Zone 1 flow temperature in central heating mode, with
external probe
Zone 1 flow temperature in cooling mode, with exter-
nal probe
Flow temperature in central heating mode without
external probe
Flow temperature in cooling mode without external
probe
Zone 2 mixed flow temperature in central heating
mode, with external probe
Zone 2 mixed flow temperature in cooling mode, with
external probe
Key:
Rxx - "Heat regulation" menu parameter
TE - Outside temperature
TM - Flow temperature
U01 - Zone 2 flow temperature in "User" menu central
heating mode
U02 - Zone 2 flow temperature in "User" menu cooling
mode
U03
÷0
6 - Offset value compared to the curve set by the
external probe
Zx - Heating system zone
1.10 HEAT REGULATION SETTING.
By setting the parameters in the "Heat regulation"
menu, you can adjust how the system operates.
The curves
(Fig. 8)
show the default settings in
the various operating modes available both with
external probe and without.
Attention:
in case of use of the CAR
V2
, the heat
adjustment curves, in the central heating phase
only, are determined by the device itself.
Attention:
parameters R04, R05, R08, R09, R12,
R13, R16, R17 also serve to define heating and
cooling temperature ranges without thermal
regulation.