Hydraulic circuit resistance.

  A  -  Storage tank unit 

hydraulic circuit resistance

1.7  HYDRAULIC CIRCUIT RESISTANCE.

In order to guarantee sufficient DHW flow rate, 

it is important to consider the resistance of the 

storage tank hydraulic circuit to be coupled to 

the boiler. (Fig. 1-5). For correct connection of 

the storage tank unit to Immergas boilers, see the 

boiler instruction book.

1.8  KITS AVAILABLE ON REQUEST.

• Pump kit (on request). The storage tank unit 

is prepared for application of the pump kit. 

Immergas supplies a series of fittings and 

attachments that allow connection between 

the storage tank unit and domestic hot water 

system. The pump kit attachment is also 

envisioned on the template.

• Column attachment kit (on request for UB 

INOX 200 ErP) A vertical connection kit is 

envisioned for the connection of the storage 

tank unit to the column, which allows to 

connect the storage tank unit directly to the 

boiler without having to insert the connection 

pipes into the wall.

• Solar collectors kit (on request for UB INOX 

120-200 ErP) On request Immergas supplies 

complete packs for set-up, if solar collectors 

are to be used for the production of domestic 

hot water.

• Double storage tank kit in parallel (on request 

for UB INOX 200 ErP) A connection kit is 

envisioned for the connection of two storage 

tank units in parallel, which allows connection 

of the two storage tank units directly to the 

boiler without having to insert the connection 

pipes into the wall.

• Solar panels kit in parallel (on request for UB 

INOX 200 ErP) For the connection of two 

storage tank units to the solar panels without 

having to insert the connection pipes into the 

wall.

• Storage tanks pump kit in parallel (on request 

for UB INOX 200 ErP) For the connection 

of two storage tank units to the recirculation 

pump pipes without having to insert the 

connection pipes into the wall.

• Electronic anode kit (on request).

 

(Not available for UB INOX 80 ErP).

  Direct current is made to circulate between the 

device and the tank to be protected via a special 

titanium anode.

  Use the fitting present on the storage tank upper 

flange for installation of the anode (Free fitting 

for UB INOX 200 ErP, or replacing the anode 

present in the UB INOX 120 ErP).

The above-mentioned kits are supplied complete 

with instructions for assembly and use.

H

ea

d (kP

a)

H

ea

d (kP

a)

H

ea

d (kP

a)

Flow rate (l/h)

Flow rate (l/h)

Flow rate (l/h)

H

ea

d (m H

2

O)

H

ea

d (m H

2

O)

H

ea

d (m H

2

O)

Содержание INOX 200 ErP

Страница 1: ... 1 038279ENG Instruction and recommendation booklet IE UB INOX 80 120 200 ErP Storage tank ...

Страница 2: ......

Страница 3: ...ions and by an authorised company which has specific technical expertise in the system sector as required by Law Improper installation or assembly of the Immergas appliance and or components accessories kit and devices can cause unexpected problems to people animals and objects Read the instructions provided with the product carefully to ensure a proper installation Maintenance must be carried out...

Страница 4: ...els only 7 1 7 Hydraulic circuit resistance 8 1 8 Kits available on request 8 1 9 Main components 9 2 Instructions for use and maintenance 10 2 1 Cleaning and maintenance 10 2 2 Emptying the storage tank unit 10 2 3 Case cleaning 10 2 4 Decommissioning 10 2 5 Control panel 10 3 Control and maintenance 11 3 1 Hydraulic diagram 11 3 2 Yearly appliance check and maintenance 11 3 3 Casing removal 12 3...

Страница 5: ...centre which has specifically trained staff and original spare parts Do not attempt to modify or repair the appliance alone Failuretocomplywiththeaboveimpliespersonal liability and invalidates the warranty Installation Standards These storage tanks have been designed for floor installation they must be used for the storage of domestic hot water and similar purposes They have not be designed for wa...

Страница 6: ... which allow to notably reduce hot water production times This storage tank unit manufacturedwithstainlesssteelcasingand bottoms guarantees long duration through time The assembly concepts and welding T I G are implemented to the minimum detail to ensure maximum reliability The upper inspection flange ensures practical control of the storage tank unit and the coil heat exchanger pipe and easy inte...

Страница 7: ...ont casing 1 and remove the hole plug plaque 2 unscrewing the 3 fixing screws 3 Solar control unit fixing Fig 1 4 Fix the screw 8 onto the support sheet steel 9 paying attention to leave a couple of mm between the head of the screw and the support sheet steel Remove the lid 6 from the solar control unit 7 loosening the screw 5 Attach the upper part of the solar control unit 7 to the screw 8 Block ...

Страница 8: ...mergas supplies complete packs for set up if solar collectors are to be used for the production of domestic hot water Double storage tank kit in parallel on request for UB INOX 200 ErP A connection kit is envisioned for the connection of two storage tank units in parallel which allows connection of the two storage tank units directly to the boiler without having to insert the connection pipes into...

Страница 9: ...ss steel storage tank unit 200 litre stainless steel storage tank unit Key 1 Stainless steel coil for storage tank 2 Domestic hot water probe 3 Magnesium anode 4 8 bar safety valve 5 Storage tank emptying cock 6 Thermometer probe 7 DHW expansion vessel 8 Coil that can be coupled to solar panels 9 Solar panels probe Optional ...

Страница 10: ...horised local firm 2 2 EMPTYING THE STORAGE TANK UNIT To drain the storage tank use the special valve in the lower part of the storage tank Part 5 Fig 1 6 Before draining ensure that the DHW inlet valve is closed 2 5 CONTROL PANEL Key 1 Hole plug plaque 2 Storage tank unit thermometer 2 3 CASE CLEANING Use damp cloths and neutral detergent to clean the storage tank casing Never use abrasive or pow...

Страница 11: ...CHECK AND MAINTENANCE The following checks and maintenance should be performed at least once a year Visually check for water leaks or oxidation from on connections Check visually that the safety and control devices have not been tampered with and in particular the DHW regulation NTC probe Check the integrity of the storage tank Magnesium anode Check the state of the internal coil Check the presenc...

Страница 12: ...20 ErP UB INOX 200 ErP Storage tank useful capacity l 80 120 200 Domestic hot water side maximum pressure bar 8 8 8 DHW side maximum temperature C 99 99 99 Domestic hot water expansion vessel l 4 0 5 0 8 0 Dispersions kWh 24h 2 49 2 54 3 42 Coil thickness mm 0 8 0 8 0 8 Coil length mm 10350 Lower coil length mm 3850 6500 Upper coil length mm 8400 10700 Coil exchange surface m2 0 65 Lower coil exch...

Страница 13: ...04W 80L E UB INOX 80 ErP A B C D E F G 143W 200L F UB INOX 200 ErP A B C D E F G 106W 120L UB INOX 120 ErP E UB INOX 80 ErP UB INOX 200 ErP UB INOX 120 ErP 3 6 PRODUCT DATA SHEET IN COMPLIANCE WITH REGULATION 812 2013 ...

Страница 14: ......

Страница 15: ......

Страница 16: ...immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038279ENG rev ST 001937 000 05 15 Inglese per IRLANDA IE ...

Отзывы: