Hydraulic circuit resistance.
A - Storage tank unit
hydraulic circuit resistance
1.7 HYDRAULIC CIRCUIT RESISTANCE.
In order to guarantee sufficient DHW flow rate,
it is important to consider the resistance of the
storage tank hydraulic circuit to be coupled to
the boiler. (Fig. 1-5). For correct connection of
the storage tank unit to Immergas boilers, see the
boiler instruction book.
1.8 KITS AVAILABLE ON REQUEST.
• Pump kit (on request). The storage tank unit
is prepared for application of the pump kit.
Immergas supplies a series of fittings and
attachments that allow connection between
the storage tank unit and domestic hot water
system. The pump kit attachment is also
envisioned on the template.
• Column attachment kit (on request for UB
INOX 200 ErP) A vertical connection kit is
envisioned for the connection of the storage
tank unit to the column, which allows to
connect the storage tank unit directly to the
boiler without having to insert the connection
pipes into the wall.
• Solar collectors kit (on request for UB INOX
120-200 ErP) On request Immergas supplies
complete packs for set-up, if solar collectors
are to be used for the production of domestic
hot water.
• Double storage tank kit in parallel (on request
for UB INOX 200 ErP) A connection kit is
envisioned for the connection of two storage
tank units in parallel, which allows connection
of the two storage tank units directly to the
boiler without having to insert the connection
pipes into the wall.
• Solar panels kit in parallel (on request for UB
INOX 200 ErP) For the connection of two
storage tank units to the solar panels without
having to insert the connection pipes into the
wall.
• Storage tanks pump kit in parallel (on request
for UB INOX 200 ErP) For the connection
of two storage tank units to the recirculation
pump pipes without having to insert the
connection pipes into the wall.
• Electronic anode kit (on request).
(Not available for UB INOX 80 ErP).
Direct current is made to circulate between the
device and the tank to be protected via a special
titanium anode.
Use the fitting present on the storage tank upper
flange for installation of the anode (Free fitting
for UB INOX 200 ErP, or replacing the anode
present in the UB INOX 120 ErP).
The above-mentioned kits are supplied complete
with instructions for assembly and use.
H
ea
d (kP
a)
H
ea
d (kP
a)
H
ea
d (kP
a)
Flow rate (l/h)
Flow rate (l/h)
Flow rate (l/h)
H
ea
d (m H
2
O)
H
ea
d (m H
2
O)
H
ea
d (m H
2
O)
Содержание INOX 200 ErP
Страница 1: ... 1 038279ENG Instruction and recommendation booklet IE UB INOX 80 120 200 ErP Storage tank ...
Страница 2: ......
Страница 14: ......
Страница 15: ......