13
STESkW ed 05/06
EOLO Star 23 kW
Technical Documentation
Technical Documentation
Coupling type vertical concentric kit Ø 80/125.
The exhaust pipe (80 mm Ø) is fitted inside the aspiration
pipe (125 mm Ø).
Connection to the boiler is done using a flange (2) that, by
means of the 60/100-80/125 adapter (3) and necessary ex-
tensions, is connected to the specific aspiration and exhaust
terminal 80/125 with aluminium tile (6).
The maximum overall permitted length is
12.2 straight verti-
cal metres.
Coupling type vertical concentric kit Ø 60/100.
The exhaust pipe (60 mm Ø) is fitted inside the aspiration
pipe (100 mm Ø).
Connection to the boiler is done using a flange (2) that, by
means of the necessary extensions, is connected to the specific
aspiration and exhaust terminal 60 /100 with aluminium
tile.
The maximum overall permitted length is
4.7 straight verti-
cal metres.
80/80 Ø coupling type separator kit.
Both pipes are 80 mm in diameter.
Connections to the boiler are done using the two specific
flanges that allow discharge (4) from the centre fitting and
aspiration (3) from one of the two side holes.
The maximum permitted length
(aspi exhaust)
is
33
straight horizontal metres and 41 straight vertical metres.
To avoid condensate problems, the exhaust pipe is limited to
a
maximum of 5 metres
.
80/80 Ø insulated coupling type separator kit.
Both pipes are 80 mm in diameter.
Connections to the boiler are done using the two specific
flanges that allow discharge (4) from the centre fitting and
aspiration (3) from one of the two side holes.
Insulation is by way of the seals (6) which create an air gap
with the external concentric 125 mm Ø pipe.
The maximum permitted length is
33 straight metres
(aspira-
tion + exhaust)
.
To avoid condensate problems, the exhaust pipe is limited to
a maximum
of 12 metres.
1
2
3
4
6
5
7
8
4
6
5
1
3
2
7
8
5
9
7
5
4
1
3
2
5
6
7
8
8
9
10
http://serviceimmergas.ro