Indications and malfunctions.
The EOLO Mini kW Special boiler signals malfunctions with
the flashing of one or more LEDs as shown in the table below.
The error code is visually displayed on the remote control
Operating signals
LED
Remote display
Boiler powered but there is no flame
one of the LEDs from 4 to 8 on
Burner on
LED 1 on
--
Boiler working in the d.h.w. mode
LED 2 on
Boiler working in the central heating mode
LED 3 on
Chimneysweep function on
LED 2 and 3 flashing
simultaneously (
)
07
Connection to the Remote Control
LED 2 and 3 on fixed
(
)
Signaled malfunction
LED
flashing
Remote display
Remote Control malfunction, offline, not compatible or
RS232 offline
LED 2 and 3 flashing
alternately (
)
(CAR=E31) (CRD=00E)
No ignition malfunction
LED 6 ( )
01
Flue pressure switch malfunction
LED 8 (
)
11
Insufficient circulation
LED 4 (
)
27
Flow NTC probe malfunction
LED 5 (
)
05
Overheating safety thermostat malfunction
LED 7 ( )
02
Electromechanical contacts malfunction
LED 2 ( ) and LED 7 ( )
flashing simultaneously
02 + 04
flashing alternately
Parasitic flame malfunction
LED 1 ( ) and LED 7 ( )
flashing simultaneously
02 + 20
flashing alternately
if installed (CAR or CRD) by means of a numerical code
preceded or followed by the letter E (i.e. for CAR = Exx, for
CRD = xxE).