43
STEkW ed 12/06
EOLO Maior kW
Technical Documentation
Technical Documentation
- The flues temperature values refer to an air inlet temperature
of 15°C.
- Data relative to domestic hot water performance refer to a
dynamic inlet pressure of 2 bar and an inlet temperature of 15°C;
these values can be measured at boiler outlet considering that to
achieve these values it is necessary to mix with cold water.
- Maximum sound power emitted when the boiler is working
is < 55dBA. This measurement refers to tests in a semi free
field with the boiler working at full power and with the
extension of the flue accessories complying with product
standards.
EOLO Maior 32 kW technical data.
Nominal heat input
Minimum heat output
Nominal heat output (working)
Minimum heat output (working)
Working heat performance at nominal output
Working heat performance at 30% load of nominal output
Loss of heat at shell with burner On/Off
Loss of heat at stack with burner On/Off
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
34,4 (29579)
12,5 (10750)
32,00 (27520)
10,5 (9030)
93,0
91,5
0,50 / 0,46
6,50 / 0,01
G20
G30
G31
Gas nozzle diameter
Supply pressure
mm
mbar (mm H
2
O)
1.35
20 (204)
0.79
29 (296)
0.79
37 (377)
Max. operating pressure of heating circuit
Max. operating temperature of heating circuit
Adjustable heating temperature
Total volume of heating expansion vessel
Expansion vessel preloading
Generator water content
Available head with a flow rate of 1000 l/h
Working heat output for the production of hot water
D.h.w. adjustable temperature
D.h.w. flow limiting device at 2 bar
D.h.w. circuit min. (dynamic) pressure
D.h.w. circuit maximum operating pressure
Minimum domestic hot water run off
Specific flow rate (∆T 30°C)
Specific flow rate in continuous duty (∆T 30°C)
Full boiler weight
Empty boiler weight
bar
°C
°C
l
bar
l
kPa (m H
2
O)
kW (kcal/h)
°C
l/min
bar
bar
l/min
l/min
l/min
kg
kg
3
90
35 - 85
7,4
1,0
2,3
39,42 (4,0)
32,00 (27520)
30 - 60
9,0
0,3
10
≤ 2,0
14,8
15,3
49,5
46,0
Electrical connection
Rated power input
Installed electrical power
Power absorbed by the circulator
Power absorbed by the fan
Appliance electrical system cutout
V/Hz
A
W
W
W
-
230/50
0,96
170
98
60
IPX4D
G20
G30
G31
Rated power fumes mass flow
Minimum power fumes mass flow
CO
2
at Q. Nom./Min.
CO at 0% of O
2
at Q. Nom./Min.
NO
X
at 0% of O
2
at Q. Nom./Min.
Fumes temperature at nominal output
Fumes temperature at minimum output
kg/h
kg/h
%
ppm
ppm
°C
°C
66
67
7,5 / 2,5
110 / 70
160 / 100
122
116
68
70
8,4 / 2,8
95 / 77
211 / 111
121
115
70
72
8,1 / 2,7
60 / 80
210 / 100
118
113
NO
X
class
NO
X
weighted
CO weighted
-
mg/kWh
mg/kWh
2
190
56
Type of appliance
C12 /C32 / C42 / C52 / C82 / B22 / B32
Category
II2H3+