3.13 VICTRIX SUPERIOR 2021 - DIM ERP CONNECTION WITH C.A.R.
V2
AND WIRELESS PROBES
Key:
1 - Low voltage connection terminal board
2 - Wireless Concentrator
3 - DIM ERP zones control unit
4 - External probe (optional)
5 - System flow probe (optional)
6 - DIM ERP zones control unit
7 - Zone 1 CAR
V2
8 - Zone 1
9 - Zone 2 wireless room probe
10 - Zone 2
11 - Zone 3 wireless room probe
12 - Zone 3
13 - DIM ERP 3 Zone
The Zones control unit will receive the following from the boiler:
- Enabling zone mode (Summer, Winter mode, etc.)
- Temperatures adjusted on the boiler panel for mixed zones (where possible);
- External temperature probe connected to boiler;
- Zone activation from boiler panel (or Dominus if present).
-Zone 1 activation from CAR
V2
.
The boiler will receive the following from the Zones control unit:
- Central heating request from Room Thermostat;
- Boiler flow temperature correlated to the zones request.
- Error codes of the faults present on the zone control unit