Immergas 3.030072 Скачать руководство пользователя страница 3

3

I

MPORTANT  

RECOMMENDATIONS

WARNINGS.

This device may only be used 

by adult users whose physical, 

sensory or mental abilities are 

not impaired.

This instruction manual (User 

section) and/or the operating 

instructions should be read by 

skilled technical staff before 

using this appliance.

Children must be supervised 

to ensure they do not play 

with the appliance.

This appliance can be used by 

children under the age of 8 

and by persons with reduced 

physical, sensory or mental 

capabilities, or lack of experi-

ence or required knowledge 

under the supervision of a 

person responsible for their 

safety or who is aware of the 

safe use instructions and of 

the risks they run. Children 

must not play with the appli-

ance. Cleaning and mainte-

nance by the user must not be 

carried out by unsupervised 

children. 

This appliance has been de-

signed to serve one residential 

housing unit only (and simi-

lar) subject to assessment of 

the energy requirement for 

domestic hot water; it is not 

a heating system pursuant to 

the legislation in force.

INSTALLATION.

Warning:

 due to its weight 

(from 80 to 111 kg depending 

on the version), this appliance 

must be handled with care 

to avoid injury to persons or 

damage to property and to 

the product itself. Installation 

must therefore be performed 

taking into account the fol-

lowing instructions:

- install the appliance in a 

frost-free room. The warran-

ty does not cover any appli-

ance breakdown caused by 

excessive pressure due to the 

safety valve blocking because 

of ice.

- Ensure the floor on which the 

appliance is to be installed is 

suitable to withstand the 

appliance's own weight and 

that of the water content 

(approximately from 197 to 

270 litres, according to the 

version). It is recommended 

to perform a structural as-

sessment by the designer of 

the dwelling.

- If the storage tank is mounted 

on a false ceiling, under the 

roof or above a living area, it 

is mandatory to install a drip 

tray to be connected to the 

drain.

- Suitably aerate the installa-

tion room in the event the 

appliance is to be installed in 

a room and/or in a position 

where the ambient temper-

ature is always higher than 

35°C.

- In a bathroom, do not install 

this product in volumes V0, 

V1 and V2. Install the device 

in the V2 volume if the di-

mensions allow it.

  

- This device is intended for 

use up to a maximum height 

of 2000 m.

- Position the appliance in an 

accessible area and at such 

a distance from the wall to 

permit correct maintenance 

/ accessibility (Parag. 2.1).

- Refer to the installation dia-

grams (Parag. 2.1).

Warning:

 failure to comply 

with recommended installa-

tion procedures, especially 

those related to the room 

volume below the minimum 

of 20 m

3

, may significantly 

reduce system performance.

- It is recommended to pro-

vide suitable shut-off valves 

on the hydraulic connection 

to allow for any routine and 

extraordinary maintenance 

operations which might re-

quire emptying/filling the 

water heater.

- In order to prevent any sta-

bility and safety issues, it 

is obligatory to secure the 

boiler to the floor, on a flat 

surface, using the fastening 

anchors supplied.

Содержание 3.030072

Страница 1: ...RAPAX 200 V3 RAPAX 200 SOL V3 RAPAX 300 V3 RAPAX 300 SOL V3 IE Instructions and warnings Installer User Maintenance technician 1 043869ENG 1 043869ENG...

Страница 2: ...alve 7 Fan 8 Compressor 9 User terminal board 10 Immersion heater 11 Domestic hot water sensor 12 High pressure sensor 13 Compressor protection thermostat 14 Compressor engage condenser Colour code ke...

Страница 3: ...ed by excessive pressure due to the safety valve blocking because of ice Ensuretheflooronwhichthe appliance is to be installed is suitable to withstand the appliance s own weight and that of the water...

Страница 4: ...exceed 0 3 MPa 3 bars and its max temperature must not exceed 85 C To perform any discharge operations of the water heater strictlyadheretothefollowing sequence disconnect the appliance from the elect...

Страница 5: ...ntenance must be performed in compliance with the regulations in force according to the manufacturer s instructions and by professionally qualified staff intended as staff with specific technical skil...

Страница 6: ...d components 8 2 Installation 10 2 1 Choosing the place of installation 10 2 2 Product installation 13 2 3 Hydraulic connection 13 2 4 Air intake connection 14 2 5 Electrical connection 14 2 6 Electri...

Страница 7: ...ified staff only POSITIONS ALLOWED DURING TRANSPORT POSITIONS NOT ALLOWED DURING TRANSPORT Technical characteristics Unit of measurement Rapax 200 V3 Rapax 200 SOL V3 Rapax 300 V3 Rapax 300 SOL V3 Dim...

Страница 8: ...urn to solar panels Rapax Sol V3 model only SC Condensate drain 20 RC 3 4 M Recirculation Rapax Sol V3 model only Ref Description Rapax 200 V3 Rapax 200 Sol V3 Rapax 300 V3 Rapax 300 Sol V3 A Condensa...

Страница 9: ...piral unit 9 Fan 10 Spiral elastic 11 Terminal board unit Not shown manual dielectric connection con densate draining pipe safety unit 12 Front cover 13 Compressor 14 Compressor coating 15 Compressor...

Страница 10: ...ferably insulated from the home s heated rooms Recommended room underground or base ment room where the temperature is higher than 10 C all year round garage boiler room with the exception of rooms wh...

Страница 11: ...and recovery of waste calories from washing machines and tumble dryers Room in basement recovery of free calories released by the floor and walls of the base ment 2nd configuration installation in a h...

Страница 12: ...y harmful for the duration in service of your water heater Connection to an attic In the presence of inadequate insulation between the building and the relative attics this type of installation may in...

Страница 13: ...th a permanent downward gradient to remove any expansion water generated by the heating process or drainage water coming from the water heater itself The pipes used must withstand a temperature of 85...

Страница 14: ...ductors with 2 5 mm section Installation shall consist of a circuit breaker or 16A multi pole fuse with contacts compliant with regulations in force A 30 mA differential circuit breaker If the power c...

Страница 15: ...15 2 11 2 12 The ducts must be fitted to the adjustable air intake and outlet vents Specific cable duct...

Страница 16: ...B B2 DHW probe K1 Domestic hot water unabling relay R1 Resistance 2 2 K Key A3 Integrated P C B B2 DHW probe N B With this configuration the boiler can show an error on the domestic probe Power suppl...

Страница 17: ...e screen Follow the on screen instructions carefully to set parameters date and time air ducts language recirculation photovoltaic operating time slots anti legionella system After setting the paramet...

Страница 18: ...1 Flat solar collectors 2 Electronic control unit 3 solar unit single circulation 4 Expansion vessel 5 Safety valve 6 System probe and venting unit 7 Mixing valve 8 Rapax Sol V3 Water heater 9 Non ret...

Страница 19: ...sumes operation with the initial settings The BOOST can be interrupted at any time Pause the BOOST OPERATING mode Choose the operating mode Select AUTO or MANUAL see paragraph 3 6 Operating modes ABSE...

Страница 20: ...ate or not the electrical integration support If it is off the device will never use the electrical integration in case of low temperatures a shortage of hot water is possible 3 6 SELECTING THE OPERAT...

Страница 21: ...temperature in the tank Our product permanently calculates depending on the air temperature and the water temperature which energy is cheaper This SMART Energy function can decide to start heating wi...

Страница 22: ...ing Fill the water heater by leaving a hot water tap open if the water flows it indicates that the water heater is full Check the water tightness of the seal and only then replace the thermostat and i...

Страница 23: ...or out of measurement range from 20 to 110 PDC stoppage Central heating C H in ELEC Check the connections reference A4 and the correct application of the probe on the pipe Check the fan operation and...

Страница 24: ...aporator works on the fan works on the compressor etc N B it is essential to disconnect the power cable on the terminal board so that the rear cover of the heat pump can be removed Fig 4 2 Remove the...

Страница 25: ...an the filter see maintenance chapter Encrusted water heater Descale the water heater Continued water leak to the level of the safety unit outside the heating period Safety valve damaged or clogged Re...

Страница 26: ...f calibration etc Insulating sheath cast iron steel or insulat ing missing on hot water connection pipes which could cause their corrosion Faulty electrical connection incorrect earth ing inadequate c...

Страница 27: ...ditions 116 Energy efficiency in colder climate conditions 96 Energy efficiency in warmer climate conditions 130 Annual energy consumption in average climate conditions 883 kW h Annual energy consumpt...

Страница 28: ...iency in colder climate conditions 100 Energy efficiency in warmer climate conditions 141 Annual energy consumption in average climate conditions 1334 kW h Annual energy consumption in colder climate...

Страница 29: ...al energy efficiency after installation since such efficiency is affected by additional factors such as the heat loss in the distribution system and the size of the products compared to the size and f...

Страница 30: ...38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy efficiency of the set of products indicated in this sheet may not reflect the actual energy...

Страница 31: ...31...

Страница 32: ...llo RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper This instruction booklet is made of ecological paper Cod 1 043869ENG rev ST...

Отзывы: