5
Feed and RPM Stages
IML-RESI PD-Series
Hard wood:
Stage 2 (50 cm/min)
to Stage 4 (175 cm/min)
Soft wood:
Stage 3 (100 cm/min)
to Stage 5 (250 cm/min)
Utility poles:
Stage 1 (100 cm/min)
to Stage 3 (200 cm/min)
General Feed Stages:
Hard wood:
2500 RPM
Soft wood:
2500 RPM
Utility poles:
3000 RPM
General RPM Stages:
Press the black key briefly to change the feed speed. In order to change
the feed speed the main menu has to be displayed.
Please note:
These values are only guide values. They vary depending on
different wood qualities and on the status of the drilling needle.
Conduct a Measurement
IML-RESI PD-Series
Make sure the main menu is displayed. Press the instrument against the
object that has to be examined. Make sure the 45° adapter sleeve is
pressed correctly. This safety function prevents accidantal measurements-
The security system will detect the compression and displays it in the
status bar of the main menu. You are not able to start a measurement
when the adapter is not pressed correctly.
After pressing briefly the red key the drilling will start and the graphic
shown above will appear.