![IMKO Trime-GW Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/imko/trime-gw/trime-gw_operating-instructions-manual_2047648020.webp)
3.2.7
An example
A continuous-flow dryer is to be set for maize. A TRIME
®
-GW has been installed whose probe is lo-
cated in the direct vicinity of the discharge point. To start with, the product selector-switch is set to
Level 1. The dryer is started up and measurement recording commences. It is not until the moisture at
the discharge point falls below 18% that the measurements become of real interest and can be used
for the adjustment process. Analysis can start as soon as about 10 to 20 measurements are available
in the range from 12% to 18%. The following table shows that the best setting for the product selector-
switch is 7.
Table 6
Reference measurement
TRIME-GW, Level 1
TRIME-GW deviation
17.9% 24.6% 1
17.3% 17.6% 8
17.8% 17.3% 8
17.1% 16.8% 8
16.8% 16.2% 8
16.5% 15.8% 8
15.8% 16.0% 7
15.1% 15.6% 7
14.5% 14.7% 7
13.9% 14.0% 7
13.3% 13.5% 7
________________________________________________________________________________
20
Содержание Trime-GW
Страница 1: ...I publik TECH_MAN TRIME GW english GW MAN_e Temperatur_Vers2_6 doc ...
Страница 31: ...Notes _________________________________________________________________________________ 31 ...
Страница 32: ...________________________________________________________________________________ 32 ...
Страница 33: ..._________________________________________________________________________________ 33 ...
Страница 34: ...________________________________________________________________________________ 34 ...
Страница 35: ..._________________________________________________________________________________ 35 ...