background image

Caution!

 

There are no user serviceable parts inside the unit. Do not open the housing or attempt any 

repairs yourself. If exceptional problem happen, please contact related after-sale department 

or manufacturer. 

Any damage that cased by violating this manual is out of insurance, our company will not take 

the responsibility. 

Section 2. Set Up 

Installation

Controlling Board

Machine connection

Installation 

 

This machine should be mounted through the screw holes of truss. Safety wire is a must

to fix fixture well. Make sure truss and safety wire have strong load capacity to bear 3 times

weight than fixture at least.

 

This machine should be installed by qualified technician.

3

4

Safety Instruction

s

 

Please conserve this manual as operation guidance. If you sell this product to other user,

 

please make sure that they also receive this user manual.

Always make sure that you are connecting to the proper voltage and the line voltage not

 

higher than stated on the decal or rear panel of the fixture.

This lighting is intended to indoor use only. To prevent risk of fire or shock, do not expose

 

fixture to rain or moisture. Make sure there are no flammable, explosive or corrosive

 

materials surrounded in 0.5meters while operating.

The unit must be installed in a location with adequate ventilation, at least 1m away from

 

adjacent surfaces. Be sure that no ventilation slots are blocked.

Fixture may carry high heat, do not aim at objective exceeding 2 minutes.

Safe wire should be used to install machine. Bearing of safe wire should be 3 times of the

 

machine weight.

Always disconnect from the power source before servicing or replacing fuse/lamp and be

 

sure to replace with same fuse/lamp size and type. Cut off power before moving, repairing

 

and cleaning the machine.

To avoid electric shock, all fixtures must be connected to circuits with a suitable ground.

Always secure fixture using a safety chain and carrying handles. Never carry the fixture by

 

its cord.

Do not operate at ambient temperatures higher than

 40°C (104°F).

In case of failure or misfunction occurred, stop using the unit immediately. Never try to

 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or

 

malfunction. Please contact the nearest authorized technical assistance center. Buy the

 

same spare parts/components from manufacturer directly.

Make sure the power cord is never crimped or damaged.

Avoid direct eye exposure to the light source while it is on.

Do not power on and power off the fixture in a short time.

When use DMX controller, please make sure that there is no interference sources (e.g.

 

intercom, high frequency radio waves and radiation source. 

For your safe

please read this user manual carefully before turn on 

the fixture. This machine should be operated by qualified engineer

 

Содержание PARC-100E/WS

Страница 1: ...ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS INSTRUCTION MANUAL COB LED Spotlight PARC 100E WS Order No 38 8090 ...

Страница 2: ...ify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If the fixture must be returned to manufacturer it is important that the fixture be returned in the original manufacturer box and packing 1 2 Contents Section 1 Getting Started Unpacking Safety Instructions Section 2 Set Up Installation Controlling Board Machine Connectio...

Страница 3: ...at least 1m away from adjacent surfaces Be sure that no ventilation slots are blocked Fixture may carry high heat do not aim at objective exceeding 2 minutes Safe wire should be used to install machine Bearing of safe wire should be 3 times of the machine weight Always disconnect from the power source before servicing or replacing fuse lamp and be sure to replace with same fuse lamp size and type ...

Страница 4: ... and wire it between pins 2 3 of the last fixture They are also readily available from specialty retailers Complimentary signal cable can transmits signals to 20 unit fixtures at most Signal amplifier is a must to connect more fixtures and must weld a 120 ohm 1 4 watt resistor and wire it between pins 2 3 of the last fixture 5 6 Controlling Board The display is blackout automatically if there is n...

Страница 5: ... Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking and vector control Eliminate scene cross fade on controller Data link not terminated Insert termination plug in output of last fixture Defective fixture or 2 devices transmitting on link Bypass fixtures one at a time until normal operation is regained unplug both connectors and conn...

Страница 6: ...iter system is independent with detective fan working system DMX Protocol 3CH Channel Function Effect 1 Dimmer 0 255 White linear dimmer from dark to light 2 Strobe 0 1 No applicable 2 255 strobe speed from slow to fast 10 Dimmer Curve Power Limiter 0 20 standard dimmer curve 21 40 dimmer curve 1 41 60 dimmer curve 2 61 80 dimmer curve 3 81 100 dimmer curve 4 101 149 N A 150 155 3 second interval ...

Страница 7: ...l fixtures same addresses value or subject to DMX console performance Attention all fixtures use the same DMX channel 3 or 1CH Specifications Power supply Operating voltage Power consumption operation Wattage Light source Strobe Dimmer Cooling Admiss ambient temp Beam angle Control mode Channels Net weight Dimensions Connections 230 V 50 Hz 160 VA 230 V 160 VA 100 W 1x 100 W COB LED cool white 700...

Отзывы: