background image

11

Dimmer Curve

 

 

5 dimmer curves are available to call up. 

Ramp Effect 

Menu 

Tup(ms) 

Tdown(ms) 

Standard Dimmer 

Curve

 

dr-0 

Dimmer Curve 

dr-1 

980 

1010 

Dimmer Curve 

dr-2 

1210 

1320 

Dimmer Curve 

dr-3 

1600 

1710 

Dimmer Curve 

dr-4 

1850 

1980 

Master and slave:

 Set up one fixture as Master fixture (triggering), other fixtures as slave 

fixtures (receiving trigger signals), when connect the signal cable, the slave fixtures will run 

and keep function synchronism as master fixtures. 

Control more machines: 

Set up all fixtures

 

d

3

-- or d.

1

—Menu, set all fixtures same 

addresses value or subject to DMX console performance (Attention: all fixtures use the same 
DMX channel 

3

 or 

1

CH). 

Specification

s

 

Power 

s

upply

:

 

Operating voltage

:

 

Power consumption, operation

:

 

Wattage

:

 

L

ight

 source: 

 

Strobe: 

  

Dimmer: 

 

Cooling

  

Admiss. ambient temp.:   

Beam 

a

ngle 

  

Control 

m

ode

  

Channel

s

 

Net weight: 

 

Dimensions

 

Connections:  

~230 V

/50 Hz/160 VA

 

~230 V
160 VA

100

 

1x 100 W COB LED

, cool white 7000 - 7500 K

0

 

~

 

20 Hz 

different d

immer 

c

urves 

1x temperature-controlled fan

 

0

 

-

 

40 °C

60° ( can be adjusted by barn door)

 

DMX512/Manual

3

 or 

1

 DMX channels

switchable

1.5kg

W

150*

H

220*

D

245mm

 

(excluding bracket)

 

3-pole XLR (DMX in),
3-pole XLR (DMX out)

MONACOR  INTERNATIONAL  GmbH  &  Co.  KG  •  Zum  Falsch  36  •  28307  Bremen  • Germany 

www.monacor.com                                                                                 

                         

   

 

 

 

01

.

07.07

.201

7

12

Содержание PARC-100E/WS

Страница 1: ...ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS INSTRUCTION MANUAL COB LED Spotlight PARC 100E WS Order No 38 8090 ...

Страница 2: ...ify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If the fixture must be returned to manufacturer it is important that the fixture be returned in the original manufacturer box and packing 1 2 Contents Section 1 Getting Started Unpacking Safety Instructions Section 2 Set Up Installation Controlling Board Machine Connectio...

Страница 3: ...at least 1m away from adjacent surfaces Be sure that no ventilation slots are blocked Fixture may carry high heat do not aim at objective exceeding 2 minutes Safe wire should be used to install machine Bearing of safe wire should be 3 times of the machine weight Always disconnect from the power source before servicing or replacing fuse lamp and be sure to replace with same fuse lamp size and type ...

Страница 4: ... and wire it between pins 2 3 of the last fixture They are also readily available from specialty retailers Complimentary signal cable can transmits signals to 20 unit fixtures at most Signal amplifier is a must to connect more fixtures and must weld a 120 ohm 1 4 watt resistor and wire it between pins 2 3 of the last fixture 5 6 Controlling Board The display is blackout automatically if there is n...

Страница 5: ... Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking and vector control Eliminate scene cross fade on controller Data link not terminated Insert termination plug in output of last fixture Defective fixture or 2 devices transmitting on link Bypass fixtures one at a time until normal operation is regained unplug both connectors and conn...

Страница 6: ...iter system is independent with detective fan working system DMX Protocol 3CH Channel Function Effect 1 Dimmer 0 255 White linear dimmer from dark to light 2 Strobe 0 1 No applicable 2 255 strobe speed from slow to fast 10 Dimmer Curve Power Limiter 0 20 standard dimmer curve 21 40 dimmer curve 1 41 60 dimmer curve 2 61 80 dimmer curve 3 81 100 dimmer curve 4 101 149 N A 150 155 3 second interval ...

Страница 7: ...l fixtures same addresses value or subject to DMX console performance Attention all fixtures use the same DMX channel 3 or 1CH Specifications Power supply Operating voltage Power consumption operation Wattage Light source Strobe Dimmer Cooling Admiss ambient temp Beam angle Control mode Channels Net weight Dimensions Connections 230 V 50 Hz 160 VA 230 V 160 VA 100 W 1x 100 W COB LED cool white 700...

Отзывы: