11
Order No. 38.0230
BEAM-4/RGBW
Multiple
BEAM-4/RGBW
s DMX Set Up
Fig. 05
Note : Link all cables before connecting electric power
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to
run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixtures the
data link can support.
Important:
Fixtures on a serial data link must be daisy-chained in a single line. To comply with the
EIA-485 standard, no more than 30 devices should be connected on one data link.
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically
isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters
Maximum recommended number of fixtures on a DMX data link: 13 fixtures
Maximum recommended number of
BEAM-4/RGBW
s on a PowerCon link: 7 fixtures@110V
Maximum recommended number of
BEAM-4/RGBW
s on a PowerCon link: 13 fixtures@240V