5. Vertical Function – 88R & 88G only
The vertical function allows for the instrument to be laid
horizontally and a vertical line is emitted.
This function is used for;
-
Alignment of formwork or pipeline runs in external
situations
-
Alignment of internal wall, floor and ceiling layout
-
In conjunction with the plumb spot beam, which is
always 90º to the rotating beam, a set-up reference
point can be determined.
Alignment of internal wall, floor and ceiling layout
5.1 Using the Vertical Mode
Lay the instrument on a floor or board. Make sure the
instrument is approximately level ± 5º and turn on.
Instrument will level as in standard position.
All functions which can be carried out in standard
position can be performed in the vertical position i.e.
scanning, grade slope, vary speed etc.
5.2 External use with Receiver
The vertical beam can be picked up with the use of the
receiver in vertical position or 90º to normal position to
check formwork or pipeline alignment set up instrument
at the end of the run in a horizontal plane.