IMER INTERNATIONAL S.p.A
8
An electrical wire in the
motor terminal board is
disconnected
Restore the
connection *
An electrical wire in the
electrical panel is
disconnected
Restore the
connection *
The ON switch is faulty
Replace the switch *
A fuse has blown
Replace the fuse *
The thermal safety
device has been
triggered
Wait a few minutes
and try again
Difficult trolley
horizontal sliding
Dirty runners
Clean the runners
No cooling water
reaching disc
Refer to "cleaning and maintenance of the
cooling system" (par. 17.5)
Disc fails to cut
The disc is worn
Replace with new
disc
Transmission belt not
tensioned
Tighten the belts
Motor starts but disc
does not turn
Belt broken
Replacing the drive
belt
* Operation to be carried out by an electrician
Tools supplied
• double-ended wrench CH 10-13
• open ended wrench CH 36
Содержание 1188863
Страница 15: ...IMER INTERNATIONAL S p A 15 Fig 2 Fig 3 fig 4 Fig 4...
Страница 16: ...IMER INTERNATIONAL S p A 16...
Страница 18: ...IMER INTERNATIONAL S p A 18...