background image

imc CRONOS-PL/-SL/compact - Getting Started, Version 5 R 7 - 2018-06-28

© 2018 imc Meßsysteme GmbH

Index

53

TEDS connector    

T4     36
U4     37
UNI2     36

Telephone numbers: Hotline     7

     U     

uninterruptible power supply    

UPS     19

UPS    

uninterruptible power supply     19

     W     

warm-up phase     8
Warranty     5
WEEE    

Restriction of Hazardous Substances     5

     X     

XCPoE pin configuration     45

Содержание CRONOS-PL

Страница 1: ...imc Me systeme GmbH Voltastra e 5 13355 Berlin Germany 2018 imc Me systeme GmbH imc CRONOS PL SL compact Getting Started Version 5 R 7 2018 06 28...

Страница 2: ...y accept any suggestions for improvements please contact our Hotline hotline imc berlin de We reserve the right to make technical modifications of the systems Copyright 2018 imc Me systeme GmbH Berlin...

Страница 3: ...modules 13 2 2 Power supply 14 2 3 Grounding shielding of the devices 14 2 4 Grounding with the use of the included power adapter 15 2 5 Grounding with power supplied by a car battery 15 2 6 Shielding...

Страница 4: ...ation 41 4 7 1 LEMO 1B 7 pin 41 4 7 2 LEMO 1B 4 pin HANDLE 42 4 8 DSUB 9 pin configuration 43 4 8 1 Display 43 4 8 2 Modem external 43 4 8 3 GPS 43 4 9 Pin configuration of the field busses 44 4 9 1 C...

Страница 5: ...ts you suggest Where have material mistakes slipped in Which spelling or typing errors have you found Responses and other feedback should be directed to the Hotline phone e mail or by writing to imc M...

Страница 6: ...the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the rec...

Страница 7: ...be given as a lump sum because they depend on many factors of the specific application and environment such as air flow convection heat radiation balance in the environment mounting structure system c...

Страница 8: ...bH apply 1 5 Guarantee Each device is subjected to a 24 hour burn in before leaving imc This procedure is capable of recognizing almost all cases of early failure This does not however guarantee that...

Страница 9: ...tion with complaints please include a written outlining description of the problem including the name and telephone number of the sender This will help expedite the process of problem elimination For...

Страница 10: ...with the relevant regulations to perform work assigned while independently recognizing any hazards 1 8 3 Special dangers This segment states what residual dangers have been identified by the hazard a...

Страница 11: ...mpact always use the original packaging or a appropriate packaging which protects the device against knocks and impacts If transport damages occur please be sure to contact the imc Customer Support Da...

Страница 12: ...hapter Technical specifications and the application hints about the individual system in order to prevent damage to the unit through inappropriate signal connection 2 Note when designing your experime...

Страница 13: ...dividual modules are distinguished by module addresses These module addresses must be configured prior to installing the module e g DIP switch rotary switch soldered jumpers Previously existing addres...

Страница 14: ...ing all devices of the imc CRONOS series The package also includes a cable with a ready made LEMO plug which can be connected to a DC voltage source such as a car battery When using this note the foll...

Страница 15: ...he case with CRONOS PL2 The DC supply input on the device itself LEMO plug female is not galvanically isolated from the housing CHASSIS SUPPLY input is galvanically connected to CHASSIS internally Tha...

Страница 16: ...switching power adapter direct grounding is normally advisable 2 6 Shielding Also all signal leads to the device must be shielded and the shielding grounded electric contact between the shielding and...

Страница 17: ...e again that means at least releasing the connection and connecting again Signal Function Connection Remarks DSUB ON activation connect pin 10 with SWITCH or SWITCH1 permanently jumpered to SWITCH1 au...

Страница 18: ...ation circuits are shown below Pin configuration of the REMOTE plug 2 9 Potential difference with synchronized devices When using multiple devices connected via the SYNC plug for synchronization purpo...

Страница 19: ...lock and main power switch and thus not requiring manual control Activation of UPS buffering is indicated by the power control LED PWR changing from green to yellow With many imc measurement devices a...

Страница 20: ...evice imc CRONOScompact with two Li ion battery packs The batteries are equipped on the bottom imc CRONOScompact with two Li ion battery packs The batteries can be inserted easily the connections are...

Страница 21: ...ischarge Otherwise the UPS is operable as long as the battery does not prevent discharge Once the passive temperature fuse has been triggered it cannot be reset and thus renders the battery pack unusa...

Страница 22: ...5 seconds stopping the current measurement storing all data and turning off the device The following error conditions are indicated by LED signal patterns Battery is not present or cannot be detected...

Страница 23: ...fore always proceed as follows when removing the storage medium 1 Press the button 1 device is switched on 2 Status LED shines the device stops access to the storage medium 3 When the Status LED start...

Страница 24: ...upported operating system are mentioned in the datasheets and the adequate manual or getting started imc STUDIO imc DEVICES 3 2 Connecting via LAN in four steps The most common case is described below...

Страница 25: ...ings for TCP IP Warning Be careful in changing settings since if the same network card is used there may be difficulties later in the company network Please discuss this with your responsible administ...

Страница 26: ...255 The 0 and the 255 should not be used if possible due to their special significance and 2 is the computer s number and so not suitable for the measurement device Step 2 Connecting the measurement d...

Страница 27: ...hould deactivate the DHCP If it is impossible to obtain any setting values via DHCP the alternative values are used These could lead to errors in the connection different networks same IP addresses et...

Страница 28: ...Firmware Update Every software version comes with matching firmware for the hardware The software only works with devices having the right firmware Upon the first connection preparation the versions...

Страница 29: ...perform a firmware update Choose Yes Warning Do not under any circumstances deactivate the device during the firmware update If any error messages appear during the firmware update do not switch the...

Страница 30: ...he following symbols for the individual firmware components appear in the list not current firmware conforms to current standards error occurred during update procedure this option is not available on...

Страница 31: ...tes and thus no network activity Windows detects inactivity of the connection and the following mechanisms are set in motion a Windows energy saving mode switches the LAN adapter off consequently inte...

Страница 32: ...4 Lift the lid in the DSUB connection area and unfasten the nose of the slot A Pressure nut B Bend protection C Fastening screw for the devices front panel D Lid screws E Locking key Nose Slot G Slot...

Страница 33: ...lso be used for normal voltage measurement Plastic connector ACC DSUB Metal connector ACC DSUBM The Universal connector ACC DSUB M UNI2 contains an additional built in PT1000 temperature sensor provid...

Страница 34: ...imc CRONOS PL SL compact Getting Started Version 5 R 7 2018 06 28 2018 imc Me systeme GmbH 34 Pin configuration 4 3 Device models overview...

Страница 35: ...pin configuration 35 4 4 DSUB 15 pin configuration 4 4 1 Standard and Universal connector 5 V Note concerning ACC DSUB M U4 connector 5 V DSUB pin 8 for C 8 OSC 16 not available if SEN SUPPLY with 15...

Страница 36: ...imc CRONOS PL SL compact Getting Started Version 5 R 7 2018 06 28 2018 imc Me systeme GmbH 36 Pin configuration 4 4 2 Special connector...

Страница 37: ...imc CRONOS PL SL compact Getting Started Version 5 R 7 2018 06 28 2018 imc Me systeme GmbH DSUB 15 pin configuration 37 4 4 3 TEDS connector...

Страница 38: ...imc CRONOS PL SL compact Getting Started Version 5 R 7 2018 06 28 2018 imc Me systeme GmbH 38 Pin configuration 4 5 DSUB configuration of scanner SC2 32 4 5 1 Variety 8 x DSUB 15...

Страница 39: ...imc CRONOS PL SL compact Getting Started Version 5 R 7 2018 06 28 2018 imc Me systeme GmbH DSUB configuration of scanner SC2 32 39 4 5 2 Variety 2 x DSUB 37...

Страница 40: ...c Me systeme GmbH 40 Pin configuration 4 6 DSUB 26 pin configuration high density Note Please use the screw for a contact with Chassis Example The following picture shows the ACC DSUBM HD B4 connector...

Страница 41: ...ND SUPPLY GND SUPPLY 5 TEDS OneWire TEDS OneWire TEDS OneWire 6 SENSE SENSE Pt100 current source SENSE SENSE 7 quarter bridge completion quarter bridge completion sense for Pt100 3 wire configuration...

Страница 42: ...guration LEMO PIN AUDIO 2 MIC 1 reserved 2 IN TEDS ground 3 polarization voltage 4 IN 5 TEDS 6 positive sensor supply 7 negative sensor supply housing device ground 4 7 2 LEMO 1B 4 pin HANDLE CRFX HAN...

Страница 43: ...ulldown to GND connected 4 8 2 Modem external DSUB PIN Signal Description Use in device 1 DCD Data Carrier Detect connected 2 RxD Receive Data connected 3 TxD Transmit Data connected 4 DTR Data Termin...

Страница 44: ...onal CAN Ground connected 7 CAN_H dominant high bus line connected 8 nc reserved error line do not connect 9 nc reserved do not connect 4 9 2 LIN Bus DSUB 9 DSUB PIN Signal Description 1 nc 2 nc 3 LIN...

Страница 45: ...line channel B 5 GND FlexRay ground 6 nc 7 BP channel A positive bus line channel A 8 BP channel B positive bus line channel B 9 nc Option Two DSUB 9 connectors CON1 and CON2 with one channel each DS...

Страница 46: ...ND GND 14 Tx2B sending channel 2B 7 Rx4A receiving channel 4A 7 Rx4A receiving channel 4A 15 GND GND 15 GND GND 8 Rx4B receiving channel 4B 8 Rx4B receiving channel 4B CON 2 ARINC Interface with 8 Rx...

Страница 47: ...c 8 DATA A Line 9 nc 4 9 9 MVB Bus DSUB 9 EMD connector with double pin configuration DSUB PIN Signal Description as Terminator plug 1 A1 Data_P data line A jumper to 6 2 A1 Data_N data line A jumper...

Страница 48: ...onnection via a push button will initiate activation deactivation Note power up from internal battery is supported 2 SWITCH1 activation only from external power supply connect pin 3 with ON static per...

Страница 49: ...mendments product package new network cable with latch protection Amendments and bug fix in Version 5 R 4 March 23rd 2016 Chapter Amendments Removable storage Notes on how to remove the storage medium...

Страница 50: ...light injury if not avoided Danger of electric shock warns of danger from electrical voltages at the measurement object which are conducted into the measurement inputs The device itself does not produ...

Страница 51: ...channels 34 DIN EN ISO 9001 5 Display pin configuration 43 DSUB 26 connector 40 DSUB 9 GPS receiver 43 DSUB 9 modem pin configuration 43 E ElektroG 5 EMC 5 EtherCAT RJ45 45 exchanging modules 13 F FC...

Страница 52: ...pin configuration XCPoE 45 pin configuration REMOTE 17 pin configuration scanner CRPL SC2 32 2 x DSUB 37 39 pin configuration scanner CRPL SC2 32 8 x DSUB 15 38 pin configuration supply plug LEMO 14...

Страница 53: ...8 imc Me systeme GmbH Index 53 TEDS connector T4 36 U4 37 UNI2 36 Telephone numbers Hotline 7 U uninterruptible power supply UPS 19 UPS uninterruptible power supply 19 W warm up phase 8 Warranty 5 WEE...

Отзывы: