About the IE-iMcV-Gigabit  

 

NOTE 

Unless noted otherwise, all references to the IE-iMcV-Gigabit in this manual are also 
applicable to the IE-iMcV-Gigabit TX/SFP. 

The SNMP manageable IE-iMcV-Gigabit Module provides a single conversion 
between 1000 Base-T twisted pair and 1000 Base-SX/LX fiber.  Each IE-iMcV-Gigabit 
includes one RJ-45 connector and one pair of SC fiber optic connectors, and/or an 
SFP port, which can support any fiber type; dual strand available in LC connectors, 
and Single Strand Fiber SFPs available in SC connectors.  IE-iMcV-Gigabit Modules 
install into any modular, SNMP manageable iMediaChassis, as well as the 
MediaChassis series, which is unmanaged.  The IE-iMcV-Gigabit offers an extended 
temperature range of -40C to +85C; when installed in an IE-MediaChassis/1 or 2, 
available in AC and DC, the module can be installed in challenging heat or cold-
related environments.  

 

NOTE 

All IE-iMcV-Gigabit Modules, including 1300 nm multi-mode and 1310 nm single-mode 
(TX/LX), 850 nm multi-mode fiber (TX/SX) and single-strand versions (TX/SSLX) will be referred 
to as IE-iMcV-Gigabit throughout this guide except where differences need to be indicated. 

Installing an iMcV-Module

 

iMcV-Modules install in IMC Networks’ SNMP manageable iMediaChassis series or in 
any MediaChassis.   
 
To install an iMcV-Module: 
1.

 

Remove the blank bracket covering the slot where the module is to be installed 
by removing the screws on the outside edges of the bracket.   

2.

 

Slide the iMcV-Module into the chassis, via the cardguides, until the module is 
seated securely in the connector.   

3.

 

Secure the module to the chassis by tightening the captive screw.   

4.

 

Save any “blanks” removed during installation for future use if the configuration 
requirements change. 

Configuration Instructions 

IE-iMcV-Gigabit Modules have user-configurable features.   Refer to the matrix for 
configuring both managed (via an SNMP compatible management application such as 
iView²) and unmanaged IE-iMcV-Gigabit Modules.   

Содержание IE-iMcV-Gigabit

Страница 1: ...IE iMcV Gigabit Operation Manual...

Страница 2: ...er To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory...

Страница 3: ...aged Modules 2 Configuration Control 2 LinkLoss FiberAlert and Link Fault Pass Through 4 Link Fault Pass Through LFPT 5 Additional Gigabit Features 6 LED Operation 7 Installation Troubleshooting 8 Spe...

Страница 4: ...ments NOTE All IE iMcV Gigabit Modules including 1300 nm multi mode and 1310 nm single mode TX LX 850 nm multi mode fiber TX SX and single strand versions TX SSLX will be referred to as IE iMcV Gigabi...

Страница 5: ...saved configurations The IE iMcV Gigabit will not override the module s configuration Replacing the same type of iMcV Module If the DIP Switch settings are the same as the settings on the removed iMc...

Страница 6: ...he modules and then configure them via software to match the same settings Unmanaged Modules Before installing configure the IE iMcV Gigabit Module for desired features The diagram indicates the avail...

Страница 7: ...er transmitters but normally has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end The combination of FiberAlert and LinkLoss allows this...

Страница 8: ...rator is notified of a fault and can quickly determine where a cable fault is located WARNING Enable FiberAlert on one side of a media conversion only Enabling it on both sides would keep both transmi...

Страница 9: ...hes today typically function as Masters IMC Networks recommends configuring IE iMcV Gigabit as indicated in the table DIP Switch Default Setting S1 1 ON Preferred OFF Forced FX Negotiation on IE iMcV...

Страница 10: ...plex Mode on the RJ 45 connector FXLL Glows green when FX LinkLoss is enabled on the port Blinks when a fault occurs on the fiber port and actively disables the copper port TXLL Glows green when TX Li...

Страница 11: ...tures interference with testing If using a high powered device which is designed for long distance installations for a short distance installation the fiber transmitters may overdrive the receivers an...

Страница 12: ...to 185 F 40 C to 85 C Storage Temperature 130 158 F 25 85 C Humidity 5 95 non condensing Power Consumption Typical IE iMcV Gigabit w LFPT 0 55Amp Fiber Optic Specifications For fiber optic specificat...

Страница 13: ...10 IMC Networks Technical Support Tel 949 465 3000 or 800 624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com...

Страница 14: ...etween blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product add...

Страница 15: ...gular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following...

Страница 16: ...e information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document IE iMcV Gigabit is a trademark of IMC Networks...

Отзывы: