3
based on the last change made, while those without Configuration Control will be set
to their default settings.
NOTE
If the end user has a mixture of standard iMcV-Modules as well as Configuration Control
iMcV-Modules, it is important to understand how SNMP and DIP Switches will impact the
cards depending on their capability. Standard iMcV-Modules cannot be upgraded to
Configuration Control capability, so it is strongly recommended to set the DIP Switches on
the modules and then configure them via software to match the same settings.
Unmanaged Modules
Before installing, configure the IE-iMcV-Gigabit Module for desired features. The
diagram indicates the available features and settings for the module. After configuring
the switch for the desired settings, install the module and connect the appropriate
cables. For further information, refer to the Installing an iMcV-Module section.
DIP Switch on S1
Feature
Default Setting
1
Preferred / Forced
ON
2
Factory use – Do Not Change
ON
3
TX Link Loss (TXLL)
OFF
4
Fiber Alert (FA)
OFF
5
FX Auto Negotiation
ON
6
FX Link Loss (FXLL)
OFF
7
SFP Speed Select LOW
OFF
8
Factory set (Program)
OFF