When charging NiCd or NiMH batteries, divide the capacity by current, then divide the result by
11.9, set this number of minutes as the value for safety timer setting. If the charger stopped at
this time threshold, about 140% of the capacity will have been fed into the battery.
For example:
Capacity Current Safety Time
2000mAh 2.0A (2000/2.0=1000)/11.9=84 minutes
3300mAh 3.0A (3300/3.0=1100)/11.9=92 minutes
1000mAh 1.2A (1000/1.2=833)/11.9=70 minutes
Safe timer Calculation
Safe timer Calculation
The program is only suitable for charging/discharging Lithium-polymer batteries with a nominal
voltage of 3.3/3.6/3.7V/cell. Different batteries have different charge technique. There are two
methods termed as constant voltage and constant current. The charge current varies according
to battery capacity and specification. The final voltage is very important; it should precisely
match the voltage of the battery: LiPo is 3.6V, LiLo is 4.1V and LiFe is 3.6V. The current and
voltage of the battery should be correctly set.
When you want to change the values of parameters, please press START/ENTER key to make it
blink and then use DES or INC to change the value. Then press START/ENTER key again to
store the value.
Lithium
Lilo/LiPo/LiFe
program
16