background image

12

Preface

Ve r s i o  H a r d w a r e   I n s ta l l a t i o n   M a n u a l

© 2015 Imagine Communications

Proprietary and Confidential

When handling chips or modules, avoid touching their pins.

Put the motherboard and peripherals back into their anti-static bags when 
not in use.

For grounding purposes, make sure your computer chassis provides 
excellent conductivity between the power supply, the case, the mounting 
fasteners and the motherboard.

Operation Safety Guidelines

Before accessing the Versio chassis:

1

Turn off all peripheral devices connected to the Versio chassis.

2

Press the power button to power off the system.

3

Unplug all power cords from the system or the wall outlets.

4

Disconnect all the cables and label the cables for easy identification.

5

Use a grounded wrist strap designed to prevent static discharge when 
handling components.

Removing the chassis covers:

After completing the above steps, you can remove the covers and install 
components/peripheral devices into the Versio chassis. See 

”Chassis 

Components Installation” on page 33

 for details.

1

Unlock and remove the screws and fasteners to remove the cover or 
components.

2

Save all the screws and fasteners for later use. (If necessary, label these 
screws or fasteners for easy identification.)

3

Follow the instruction in 

”Remove the Chassis Cover” on page 36

 to 

remove the chassis cover.

Reinstalling the chassis covers:

To maintain proper system cooling and airflow, do not operate the system 
without installing all chassis covers back to the chassis. To reinstall the chassis 
covers, please follow the steps listed below:

1

Make sure that all components and devices are securely fastened on the 
chassis and there are no loose parts/screws inside the chassis.

2

Make sure that all cables are properly connected to the connectors and 
ports.

3

Use the original screws or fasteners to install the covers to the chassis.

Warning

To avoid personal injury and 
property damage, please 
carefully follow all the 
Operation Safety Guidelines 
precisely.

Caution

For proper cooling, make sure 
to install all chassis covers 
before turning on the system. If 
this rule is not strictly followed, 
warranty may become void. Do 
not open the casing of a power 
supply. Power supplies can only 
be accessed and serviced by a 
qualified technician of the 
manufacturer.

Содержание Versio

Страница 1: ...VersioTM Edition E...

Страница 2: ...erves the right without notice to make such changes in equipment design specifications components or documentation as progress may warrant to improve the performance of the product Trademarks Product...

Страница 3: ...es 8 Safety Terms and Symbols 8 Restriction on Hazardous Substances RoHS Directive 8 Waste from Electrical and Electronic Equipment WEEE Directive 9 Safety Guidelines 10 Electrical Safety Guidelines 1...

Страница 4: ...e Pinouts 27 AB4 to RJ12 27 Pinout Reference 28 RS422 Wiring EIA 422 DB9 28 RJ RS422 PINOUT 28 AB4 RJ12 GPI PINOUT 29 RJ12 to DB9 Adapters 29 Tributary Adapter AB4 Master Controlling External Device 3...

Страница 5: ...al Loading 41 Circuit Overloading 41 Reliable Ground 42 Rack Mounting 42 Identify the Sections of the Rack Rails 42 Install Inner Rails to the Chassis 43 Install the Outer Rails to the Rack 44 Install...

Страница 6: ...Specifications 63 Broadcast I O 63 Genlock Ref In Specification 64 Audio Processing 65 SD Video Compression 65 HD Video Compression 66 Chassis 67 System Power 68 System Operating Environment 68 Integr...

Страница 7: ...Preface...

Страница 8: ...oadcast documents can be viewed or downloaded from the Harris Broadcast website at http support harrisbroadcast com Alternatively contact your customer service representative to request a document Tab...

Страница 9: ...ny item is damaged 5 Remove all packaging material from the product and its associated components before you install the unit Keep at least one set of original packaging in the event that you need to...

Страница 10: ...nt Chromium Cr V1 Polybrominated Biphenyls PBB Polybrominated Diphenyl Ethers PBDE All relevant Harris Broadcast products either comply with the legislation or are exempt For example spare parts suppl...

Страница 11: ...zardous waste to either the producers or users of these products Producers or users are required to recycle electrical and electronic equipment at end of its useful life and must not dispose of the eq...

Страница 12: ...its components Plug the Power cord s into a socket that is properly grounded before turning on the power General Electrical Safety Guidelines Be aware of the locations of the power switches on the cha...

Страница 13: ...e into contact with power circuits After accessing the interior of the chassis be sure to close the chassis with chassis covers and secure the chassis to the racks with screws ESD Safety Guidelines Th...

Страница 14: ...Unlock and remove the screws and fasteners to remove the cover or components 2 Save all the screws and fasteners for later use If necessary label these screws or fasteners for easy identification 3 Fo...

Страница 15: ...re before installing the chassis into the rack 2 Unplug the power cord s of the rack before installing the chassis into the rack 3 Make sure that the system is adequately supported Make sure that all...

Страница 16: ...14 Preface Versio Hardware Installation Manual 2015 Imagine Communications Proprietary and Confidential...

Страница 17: ...Chassis Components Chapter 1...

Страница 18: ...nications Proprietary and Confidential Overview This chapter provides details on the front and back panel components of the Versio system and includes the following topics Front Panel on page 17 Disk...

Страница 19: ...nt Panel The Versio inner front panel includes the following System Power on off button UID button LED indicators Hot swappable hard disk drives Figure 1 2 Versio Inner Front Panel Front LED Panel The...

Страница 20: ...ol panel located on the front of the chassis has five LEDs These LEDs provide you with critical information related to different parts of the system Button Description Power The main power switch is u...

Страница 21: ...n that particular drive is being accessed Red The red LED indicates an SAS3 SATA drive failure If one of the SAS3 SATA drives fail you should be notified by your system management software LED Descrip...

Страница 22: ...dundant OS and graphics media drives 6 x 120 GB SSD drives in RAID 5 Figure 1 4 Front Panel Disk Subsystems Drive Configuration See the following illustration for the detailed system drive configurati...

Страница 23: ...cement on your system may vary slightly from the graphic Figure 1 6 Versio Back Panel Motherboard I O The following details the motherboard connectors and I O Figure 1 7 Motherboard I O The IPMI LAN p...

Страница 24: ...ing Supermicro web page http www supermicro com support manuals Broadcast I O The following details the broadcast I O Figure 1 9 Broadcast I O For specification details see Broadcast I O on page 63 Vi...

Страница 25: ...connected at all times during operation therefore it is recommended that the failed module be replaced immediately to maintain full power redundancy Video I O Type Function Automation Channel Notes 1...

Страница 26: ...the procedure Note For extra insurance against power loss you might want to connect the two power supply modules to AC outlets on different circuit breakers or connect the system to an Uninterruptible...

Страница 27: ...ck of the Versio system AB4 Fanout Cable Design A single AB4 fanout cable is provided for the serial 16 card which allows for a single VHDCI connection to the board while providing 16 individual RJ co...

Страница 28: ...gths The standard cables provided are 7 ft 210 cm in total length with a 3 ft 90 cm portion a single cable from the VHDCI connector carrying all 16 ports and the remaining 4 ft 120 cm individual cable...

Страница 29: ...E 2 44 5 TX 11 5 RX 4 3 45 5 RX 12 6 TX 1 6 F 2 46 6 TX 13 6 RX 4 3 47 6 RX 14 7 TX 1 7 G 2 48 7 TX 15 7 RX 4 3 49 7 RX 16 8 TX 1 8 H 2 50 8 TX 17 8 RX 4 3 51 8 RX 18 9 GPO1 1 9 J 2 52 9 GPI1 19 9 GPO...

Страница 30: ...STER SMPTE TRIB HARRIS MSTR RJ12 AB4 HARRIS TRIB RJ12 HARRIS MSTR RJ45 DB9 M RS422 EIA 422 DB9M SMPTE SMPTE MASTER DB9F SMPTE SMPTE TRIB RJ12 ADC HARRIS MASTER RJ1 2 HARRIS TRIB RJ45 D Ser HARRIS MAST...

Страница 31: ...idential AB4 RJ12 GPI PINOUT RJ12 to DB9 Adapters There are two RJ12 to DB9 adapters available tributary and master Figure 1 12 RJ12 to DB9 Adapter both models RJ12 1 GPI O 2 GPI I 3 GPI I GND 4 GPI O...

Страница 32: ...ble part number 134 000721Q 00 Master Adapter External Device MASTER Controlling AB4 Slave The following is based on AB4 using the MASTER fanout cable part number 134 000722Q 00 Harris 134 000721Q 00...

Страница 33: ...System Installation Chapter 2...

Страница 34: ...agine Communications Proprietary and Confidential Overview This chapter provides information about installing your Versio system and includes the following topics Chassis Components Installation on pa...

Страница 35: ...from the system or wall outlets 3 Disconnect all the cables and label the cables for easy identification 4 Use a grounded wrist strap designed to prevent static discharge when handling components Rem...

Страница 36: ...extends the drive carrier handle 2 Swing the handle out fully and pull the tray straight out Figure 2 1 Tray Removed from Chassis Install Hard Drive into a Drive Carrier 1 Remove the four Phillips he...

Страница 37: ...included in the HDD bag of your accessory box Figure 2 2 Drive Tray with SSD 5 Insert the drive and drive carrier into its bay vertically keeping the carrier oriented so that the release button is on...

Страница 38: ...mory modules IO cards and mid plane fans 1 Loosen the Knurled captive screw and slide the cover backwards toward the rear of the chassis 2 Check that everything is fully seated 3 Lift the cover up and...

Страница 39: ...en vibration levels System Fan Failure Fan speed is controlled by system temperature via IPMI software If a fan fails the remaining fans will ramp up to full speed Replace any failed fan at your earli...

Страница 40: ...a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardo...

Страница 41: ...using the handle 3 Replace the failed power supply module with the same model Note The part number for the Versio power supply module is 122 100037 00 4 Push the new power supply module into the power...

Страница 42: ...etup Location Leave enough clearance in front of the rack to enable you to open the front door completely 25 inches Leave approximately 30 inches of clearance in the back of the rack to allow for suff...

Страница 43: ...he ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment c...

Страница 44: ...t with the rails provided There are a variety of rack units on the market which may mean that the assembly procedure will differ slightly from the instructions provided You should also refer to the in...

Страница 45: ...h normal use of the chassis if you decide not to use a server rack Attach the inner rail extension to stabilize the chassis within the rack Figure 2 5 Inner Rails and Extensions 1 Place the inner rail...

Страница 46: ...side of the longer outer rail You must align the pins with the slides Both bracket ends must face the same direction 2 Adjust both the shorter and longer rails to the proper distance so that the rail...

Страница 47: ...the other outer rail Figure 2 8 Outer Rails Installed Install Chassis into Rack After the inner rails and inner rail extensions are installed on the chassis and the outer rails are installed on the r...

Страница 48: ...into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting When the server has been pushed completely into the rack you should hear the locking...

Страница 49: ...ld consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number...

Страница 50: ...48 Chapter 2 System Installation Versio Hardware Installation Manual 2015 Imagine Communications Proprietary and Confidential...

Страница 51: ...Maintenance Chapter 3...

Страница 52: ...agine Communications Proprietary and Confidential Overview This chapter provides information about maintaining your Versio system and includes the following topics Hot Swap Power Supplies on page 51 S...

Страница 53: ...n LED on the failed power supply module is off The PS FAIL LED on the front of the unit is red To stop the alarm from sounding unplug the power supply module from the system Note For redundant operati...

Страница 54: ...WIM image you are capturing the current state of a specific drive on the Versio system to use for future system recovery A WIM image capture can contain extremely large files Before capturing the imag...

Страница 55: ...rty USB stick 6 From the Format Type drop down list select NTFS 7 Click the FORMAT button to format the third party USB stick Download any necessary files from the Harris Broadcast FTP site Capture th...

Страница 56: ...10 Click the Browse button beside the Step 2 field 11 Select the location and enter the name for the WIM file 12 In the Capture Image dialog select the Make Bootable checkbox 13 Click the Capture Imag...

Страница 57: ...ive and press ENTER to access the Recovery Desktop 5 On the Recovery Desktop double click the Utility Launcher icon 6 In the Harris Broadcast Utility Launcher click the Imaging button to open the NxIm...

Страница 58: ...the File menu select Apply WIM Image 15 In the Apply Image dialog click Open to access the Select the Source Image dialog Figure 3 6 Apply Image Dialog 16 In the Open dialog navigate to the Recovery...

Страница 59: ...When the process is complete click Close to return to the Recovery Desktop 20 Go to Start Computer Right click on the Recovery Boot USB drive and select Eject from the menu 21 Remove the System Recov...

Страница 60: ...ftware is not on air or actively in use Under these conditions Harris Broadcast agrees that such scans may be conducted while software applications are running but are not performing editing playback...

Страница 61: ...eeding Automatic Updates Harris Broadcast builds and ships Graphics Server systems with the Microsoft Updates feature turned off This prevents future operating system updates from automatically instal...

Страница 62: ...60 Chapter 3 Maintenance Versio Hardware Installation Manual 2015 Imagine Communications Proprietary and Confidential...

Страница 63: ...Specifications Chapter 4...

Страница 64: ...d Confidential Overview This chapter provides your Versio system specifications and includes the following topics Broadcast I O on page 63 Audio Processing on page 65 SD Video Compression on page 65 H...

Страница 65: ...Table 4 1 Versio Broadcast I O Specification Item Specification Physical HD SDI Inputs 4 Inputs via HD BNC Physical HD SDI Outputs 4 Outputs via HD BNC HD Input Output Configurations option HD SDI IN...

Страница 66: ...3 16 9 HD Aspect Ratio 16 9 Aspect Ratio Conversion Up down cross conversion support EIA 608 708 WST OP 47 caption conversion AFD aspect ratio conversion Port based aspect ratio conversion User based...

Страница 67: ...6 20 or 24 bit PCM 48kHz Compressed Audio Dolby Digital AC 3 and Dolby E pass through Table 4 4 SD Video Compression Specification Compression Profile Resolution and Frame Rate MPEG 2 l frame 4 to 15...

Страница 68: ...50fps MPEG 2 l frame 50 70 80 100 120 and 150 Mbps 4 2 2 1080i 29 97fps 720p 59 94fps 1080i 25fps 720p 50fps MPEG 2 Long GOP 18 25 35 50 60 70 and 80 Mbps 4 2 0 1080i 29 97fps 720p 59 94fps 1080i 25fp...

Страница 69: ...80i 29 97fps 720p 59 94fps 1080i 25fps 720p 50fps Table 4 5 HD Video Compression Specification Compression Profile Resolution and Frame Rate Table 4 6 Chassis Specification Item Specification Dimensio...

Страница 70: ...80 240V 60 50Hz 5 3 8 Amp DC Output 12V 700W 58 Amp 100 140V 750W 62 Amp 180 240V DC Output 5V Standby 3 Amp Power Distributor Output 5V 25 Amp 3 3V 25 Amp 12V 0 6 Amp Efficiency Level Certification 8...

Страница 71: ...N 2 x Gigabit Ethernet Intel I350 COM 1 x RS232 via DB9 IPMI IPMI Controller Renesas SH7757 BMC Dedicated IPMI LAN Interface 1x RJ45 Realtek RTL8211E PHY IPMI 2 0 Virtual Media over LAN IPMI 2 0 Keybo...

Страница 72: ...ume Graphics Media Disk Subsystem 450 GB partition in SSD RAID 5 volume Server Media Disk Subsystem 4 x 1 TB SATA RAID 3 Table 4 12 File Import and Export Details Item Details Video Files FTP to and f...

Страница 73: ...ideo playback graphic branding and master control Protocols Versio native protocol Table 4 16 Graphic Branding Details Item Details Bit Depth 32 bit 24 bit graphics RGB 8 bit alpha Graphic Video Forma...

Страница 74: ...time Clocks and Stills No practical limit Screen Coverage Up to 2x resolution Table 4 17 DVE option Details Item Details Quantity Two 2D DVEs Two DVEs on screen simultaneously Live Input Enabled by DV...

Страница 75: ...pression SD video 65 control details 71 D damage prevention 58 disk subsystems 20 drive configuration 20 DVE option details 72 E electrical safety guidelines 10 ESD safety guidelines 11 F file import...

Страница 76: ...n specification 64 reference in specifications 64 remote interface details 71 replace a failed power supply 51 S safety guidelines 10 13 standards and compliances 8 SAS SATA LEDs 19 SD video compressi...

Страница 77: ...Versio Hardware Installation Manual 2015 Imagine Communications Proprietary and Confidential W Warning LED 19 WIM image 52 apply WIM image 54 create a WIM image 52 initial image 52 Windows Automatic U...

Страница 78: ...76 Index Versio Hardware Installation Manual 2015 Imagine Communications...

Отзывы: