Approximately three seconds after powering up, the DA-6804
+
D module should
be fully operational. The module can be set to either local (card-edge) or remote
(CCS network) control, using the
J3
jumpers setting described on
page 9
.
The current software version of a DA-6804
+
D module can only be viewed using a
CCS-enabled control panel or a CCS software application. Default settings cannot
be recalled on this module.
Automatic Changeover
The signal at
SDI In_1
is distributed to 8 outputs. If the signal at
SDI In_1
is lost,
the outputs are switched to
SDI In_2
(the module must be able to detect a signal
at
SDI In_2
). Using the
Hysteresis
parameter, you can set the amount of delay
before the module switches over to
SDI In_2
, and before the problem is reported
to CCS.
When the signal returns at
SDI In_1
, the outputs automatically switch back to SDI
In_1
from
SDI In_2
.
Reclocking
The DA-D can reclock 270 Mb/s SD-SDI signals; the DA-D,
can reclock 270 Mb/s, 1.485 Gb/s, and 2.97 Gb/s SMPTE signals. If the input data
is not at one of those rates, the reclocker function will not function. Instead, the
signal will pass through the module.
Содержание DA-DH6804+D
Страница 4: ......
Страница 12: ...About This Manual x Copyright 2011 Harris Corporation...
Страница 22: ...Chapter 2 Installation 10 Copyright 2011 Harris Corporation...
Страница 28: ...Chapter 3 Operation 16 Copyright 2011 Harris Corporation...
Страница 32: ...Chapter 4 Specifications 20 Copyright 2011 Harris Corporation...
Страница 34: ...Index 22 Copyright 2011 Harris Corporation...
Страница 35: ......