Errors:

 Enables the logging of critical failures, such as the device failing to confirm 

that a transition command was executed, or when communication is lost with the 
router.  

 

Warnings:

 Enables the logging of other information reported by the router. The 1200 

series routers do not provide such information to automation; so enabling Warnings 
will have no effect on the system.  

 

Crosspoint Changes:

 Enables the logging of each transition with a timestamp from 

when it occurred.  

7.  The 

Log

 tab contains configurations for Manual Intervention Logging.  The 1200 series 

routers do not report to automation when a crosspoint change has occurred manually or 
by another controller, thus changing any of the options on the Log tab will have no effect 
on the system. 

8.  On the 

Backup

 tab, select the router that is to be used as the redundant backup router, 

or leave it set to None if there is not one.  The router that is configured here will receive 
all of the transition commands that are sent to the main device. For this reason the 
Backup router must be wired identically to the Main. There are other methods for driving 
a second switcher if this limitation cannot be accommodated. 

9. 

Cascade

 is an advanced configuration used for triggering additional crosspoint changes 

using a single event or command from the Transmission List. For more information on 
Cascade, consult the ADC-100 user manual. 

10.  The 

Wire

 tab configures the driver to operate in Simplex or Full Duplex mode: 

 

 

2 Wires

: The driver will ignore any input from the device and never report any comm. 

errors. If RS-485 operation is attempted with multiple routers (not recommended), 
this option must be used and the return lines from the switcher must be 
disconnected. The Device Server hardware is not capable of negotiation on an RS-
485 bus. 

 

4 Wires

: The driver will look for confirmation from the router that a transition has 

occurred, and retry (twice) if there is no reply.  If there is still no reply after three tries, 
the driver will stop trying and report an error (if Warnings is selected on the Reporting 

 

© 2015 Imagine Communications Corp.      

Proprietary and Confidential 

  13-May-2015| Page 6 of 7 

Содержание Evertz 1200 Series

Страница 1: ...l was originally designed to support an RS 485 bus containing a number of 10x1 switchers While it is not recommended to connect devices to ADC 100 in an RS 485 configuration there is no support for fl...

Страница 2: ...Move the ribbon cable on J29 to J23 2 Set the jumper on J26 to pins 2 and 3 toward header J23 The firmware must be configured with the appropriate communications parameters On the front panel of the 1...

Страница 3: ...ionally the Evertz router begins at address destination zero and ADC 100 is one based This means that a base address of 0 on the router is represented by destination 1 on ADC 100 If destinations 14 an...

Страница 4: ...t setting of 12 Output Crosspoints There can only be two destinations on the 1200 series but this should be set to the base address 1 see Device Setup notes The router will ignore crosspoints that are...

Страница 5: ...orbars button is pressed on the diagnostics control panel Configuration Utility or Air Client If it is set to 0 then the Colorbars button will have no action Station ID When the Transmission List Opti...

Страница 6: ...are sent to the main device For this reason the Backup router must be wired identically to the Main There are other methods for driving a second switcher if this limitation cannot be accommodated 9 C...

Страница 7: ...changes Operation Notes Before the router can be used on a Transmission List there are additional configurations required for the List A V Tables This configuration is described in the ADC 100 user g...

Отзывы: