background image

 

  

 

 

Product – ADC v11 and v12 

Topic: Evertz 1200 Series 12x2 Routing 
Switchers 

This document describes the setup and use of the Evertz 1200 series routers in the ADC-100 
environment. The modified GVG TEN-XL ASCII command protocol is used to control the Evertz 
1200 series routers. 

There are some hardware differences between the 1200 series routers and the Grass Valley 
TEN-XL routers that have required differences in implementation of the protocol for the 1200 
series routers. Since the GVG TEN-XL protocol is based on 10 input crosspoints and the Evertz 
12 x 2 router family contains 12 input crosspoints, the protocol was extended to include 
crosspoint #11 and #12.   

Additionally, the 10XL protocol was originally designed to support an RS-485 bus containing a 
number of 10x1 switchers.  While it is not recommended to connect devices to ADC-100 in an 
RS-485 configuration (there is no support for flow control on the Device Server), this driver 
supports the concept of addresses for the purpose of directing commands to one of the two 
destinations. 

Release Date: 18-August-2003 

Revision History 

Revision  Protocol 

Date 

Author 

Description 

0.1 

 

6-20-2003 

D. Klochkov 

Initial Composition 

0.2 

 

8-12-2003 

C. Kocsis 

Revision 

1.0 

 

8-18-03 

B. Flemmons 

Final 

1.1 

 

5-13-15 

 

Rebranded 

Version Used 

Model Tested:  

Evertz 1202S-AES 12x2 router 

Firmware:   

Version 1.1, build 125 

Manual:  

 

Revision 1.3.2, Feb. 2003  

 

Protocol:  Grass Valley 10XL, using addresses as destinations, with extended Evertz proprietary 
support for inputs 11 and 12 

 

 

© 2015 Imagine Communications Corp.      

Proprietary and Confidential 

  13-May-2015| Page 1 of 7 

Содержание Evertz 1200 Series

Страница 1: ...l was originally designed to support an RS 485 bus containing a number of 10x1 switchers While it is not recommended to connect devices to ADC 100 in an RS 485 configuration there is no support for fl...

Страница 2: ...Move the ribbon cable on J29 to J23 2 Set the jumper on J26 to pins 2 and 3 toward header J23 The firmware must be configured with the appropriate communications parameters On the front panel of the 1...

Страница 3: ...ionally the Evertz router begins at address destination zero and ADC 100 is one based This means that a base address of 0 on the router is represented by destination 1 on ADC 100 If destinations 14 an...

Страница 4: ...t setting of 12 Output Crosspoints There can only be two destinations on the 1200 series but this should be set to the base address 1 see Device Setup notes The router will ignore crosspoints that are...

Страница 5: ...orbars button is pressed on the diagnostics control panel Configuration Utility or Air Client If it is set to 0 then the Colorbars button will have no action Station ID When the Transmission List Opti...

Страница 6: ...are sent to the main device For this reason the Backup router must be wired identically to the Main There are other methods for driving a second switcher if this limitation cannot be accommodated 9 C...

Страница 7: ...changes Operation Notes Before the router can be used on a Transmission List there are additional configurations required for the List A V Tables This configuration is described in the ADC 100 user g...

Отзывы: