background image

 

   

 

 

 

 

 

Image Engineering 

 

Seite 

7

 von 

12

 

exposure  control  of  the  camera  is  used. This  only  applies  to  the  camSPECS  hardware  with  the 

sequential capturing mode (“Multi

-

shot”).

 

4. 

Apply dark frame subtraction. Supported image types are: TIFF, PGM, BMP, PNG, PPM and raw 

files. Take an image with the same camera exposure settings as used for the camSPECS images. 

It  will  be  subtracted  from  each  image  in  the  processing  list.  This  option  is  used  to  subtract  the 

offset value, inherent in all images, that has its origin in the dark current of the sensor. This offset 

value has a negative impact on the spectral measurement. 

 

5. 

Set the maximum allowed digital value in accordance with the 

Exposure

 guidelines given above. If 

this value is exceeded in an image, an error message is displayed.

 

6. 

Add image(s) to processing list. Supported image types are: TIFF, PGM, BMP, PNG, PPM and raw 

files (The term "raw file" means files that are created by a digital camera in "RAW

-

Mode" and are 

readable by the software 

dcraw

. This does not include raw files that do not follow any image file 

format.  You  should  convert  these  files  to  16

-

bit  Tiff  images  first.).  Depending  on  the  selected 

calibration  file  (see  item  1)  you  can  choose  one  or  more  images  that  must  contain  the  filter 

arrangement of camSPECS device. With the '+', '

-

' and 'C' buttons you can add images, remove 

one selected image or clear the whole list.   After the measurement the spectral curve of the first 

image in the list is displayed. By clicking on the other images in the list the corresponding results 

are displayed.

 

7. 

Check the advanced settings.

 

8. 

Start  the  processing  procedure.  The  filters  in  the  images  are  detected  automatically.  After  the 

detection  process  a  confirm  dialog  is  shown  where  the  ROIs  for  each  filter  can  be  manually 

repositioned  if  necessary.  By  double

-

clicking  on  the  background,  the  processing  starts.  The 

resulting spectral curves are displayed and saved to a plain text (.txt) and an XML file in the same 

directory as the original image directory. For the camSPECS version a tile image is saved to the 

same directory as the origin of the images directory assembled from the single images. Check this 

image for correct positions of the ROIs or all filters.

 

In some cases, the filters of camSPECS images may not be detected automatically. In this case 

you are guided by semi

-

automatic filter detection with some controllers which restrict a couple of 

constraints for correct detection of the filters.

 

9. 

When the measurement is done you can switch between raw and normalized RGB spectral curves 

data. 

 

10. 

Export  the  spectral  curves  to  an  image  (JPEG,  PNG,  TIFF,  BMP,  GIF)  for  documentation 

purposes.

 

 

 

 

 

Содержание camSPECS

Страница 1: ...Image Engineering GmbH Co KG Im Gleisdreieck 5 50169 Kerpen Horrem Germany T 49 2234 2273 99 99 1 0 F 49 2234 2273 99 99 1 10 www image engineering com camSPECS Quick Start Guide 31 January 2020 ...

Страница 2: ...al sensitivity iQ LED module 4 3 1 3 Validation module 4 3 1 4 Color Transforms module 4 3 1 5 ICC profile evaluation module 5 4 OPERATING INSTRUCTIONS 5 4 1 Camera settings 5 4 1 1 Camera position and lenses used 5 4 1 2 Exposure 6 4 2 Spectral sensitivity camSPECS Module 6 4 3 Spectral sensitivity iQ LED Module 8 4 4 Validation module 9 4 5 Color Transforms Module 10 4 6 ICC profile evaluation 1...

Страница 3: ...ce with suitable distance to walls Do not open the top sliding port of the housing during operation for bulb exchange Do not open the device when connected to the power supply 2 GETTING STARTED Remove the packaging material The plug for the power supply and the main switch are located at the back side of the box Connect camSPECS with a power socket and switch it on and let it run for a couple of m...

Страница 4: ...red by the camera for each of the Spectra Click the Start button The computed spectral sensitivities are displayed and a text file is saved 3 1 3 Validation module Take a picture of a ColorChecker 24 patches or ColorChecker SG 140 patches chart that was illuminated by a light source whose spectral distribution is included in the software D50 D55 D65 A C Additional spectral distribution files can b...

Страница 5: ... save pictures as linear raw files Exposure program Manual Aperture No default value ISO Speed Lowest value e g 100 Auto focus Off File type RAW 4 1 1 Camera position and lenses used Place the camera in front of the filter plate The principal axis of the lens must be aligned perpendicular to the center of the filter plate Adjust the distance between the lens and the filter plate such that the filt...

Страница 6: ...asonable exposure settings typically f 5 6 t 1 2s ISO 100 depending on camera and lens in RAW mode with Bayer pattern Check the RAW image for the highest recorded value in all RGB channels using a RAW image viewer or converter i e dcraw 4 2 Spectral sensitivity camSPECS Module 1 Select the calibration file for your camSPECS device With the and buttons calibration files can be added and removed fro...

Страница 7: ...ust contain the filter arrangement of camSPECS device With the and C buttons you can add images remove one selected image or clear the whole list After the measurement the spectral curve of the first image in the list is displayed By clicking on the other images in the list the corresponding results are displayed 7 Check the advanced settings 8 Start the processing procedure The filters in the ima...

Страница 8: ...sent 4 Check Dark Frame Subtraction to select a dark capture taken with the camera with the lens cap on or other means to ensure no light reaches the image 5 Add Spectra Folder to select the folder containing the spectral power distribution files for the desired individual LEDs that were previously saved using the Export feature in the separate iQ LED software 6 Add Image Folder to select the fold...

Страница 9: ...first column and the intensity values in the second column Columns must be separated with a tabulator The files in the calibration_files lightsource directory of the camSPECS program folder may be used as a template Format your file corresponding to these files and copy it to this folder then restart camSPECS 3 Select ColorChecker reflectance data The data used contains the spectral distribution b...

Страница 10: ...lly Double click outside ROIs to continue 7 Export the validation graph to an image JPEG PNG TIFF BMP GIF for documentation purposes 4 5 Color Transforms Module 1 Select a Camera Spectral Sensitivites file that was created by camSPECS 2 Select the desired Transform Type from those available 3 Select the desired Reference illuminant spectral distribution file for the light source of the scene adopt...

Страница 11: ...orm 7 Optionally Additional Test Data can be selected to input additional test spectra to be used to evaluate the camera transform 8 Click Start to generate the specified transform 9 The results panel shows the performance of the transform By default a visual representation of the Test data is shown in split field for each color patch 10 Display shows the results from the computed transform by def...

Страница 12: ...g and viewing 2 Select ICC profile directory selects the directory where ICC profiles are located or were saved in the CCM ICC profile creation module 3 ICC profile test image 1 selects from a list of ICC profiles To view the raw image select None 4 ICC profile test image 2 selects from a list of ICC profiles To view the image color managed for viewing on an sRGB device select the ICC profile just...

Отзывы: