Perform Setup 

 

 

25 

 

To select a submenu or a function from the screens "Self Test 1" and 
"Self Test 2", tap with your finger on the button of the screen. 

  

Assign the IP Address 

Manually Assign the IP Address 

To manually assign the IP address, proceed as follows: 

 

On the "Self Test 1" screen, tap on IP ADDRESS. 

  

 

  

Содержание WideTEK 36 DS

Страница 1: ...WideTEK 36DS Setup Instructions English 03 2017...

Страница 2: ...asic Safety Information 7 Avoiding Property Damage and Malfunctions 8 Responsibility of the Owner 9 Staff Qualifications 9 Design Features of Warning Notices 10 Formatting of Information Regarding Pro...

Страница 3: ...ssign the IP Address 25 Perform White Balance 33 Lamp On Off 37 Touch Adjust 37 Touch Test 38 Stitch Test 39 EMV Test 39 Sensor Test 39 Shutdown Scanner 40 Technical Specifications 41 WideTEK 36DS Sca...

Страница 4: ...r the wide format scanner WideTEK 36DS The WideTEK 36DS scanners are hereinafter referred to as Scanner Keep Instructions with the Scanner These instructions are a part of the scanner Please always st...

Страница 5: ...ements as illustrated below Normal text BUTTONS OF THE SCREEN PAGE Menu names Action steps Enumeration of the first level Cross references Tips contain additional information such as special informati...

Страница 6: ...filmed edited copied or distributed in whole or in part without prior written permission from Image Access GmbH Image Access GmbH 2017 All rights reserved Contact Data of the Manufacturer in Germany...

Страница 7: ...liability claims Ambient Conditions Ensure that the scanner is used exclusively under the following environmental conditions Ambient temperature during operation 5 C to 40 C Storage temperature 0 C to...

Страница 8: ...sions and Bruises Incorrect installation of the cables can cause tripping Lay the connecting cables so that no one can trip over them The scanner weighs 64 kg Only carry the scanner with a second pers...

Страница 9: ...owner must ensure that only qualified personnel carry out the setup of the scanner Staff Qualifications The staff that carries out the setup of the scanner must have knowledge in installing connecting...

Страница 10: ...ld lead to death or serious injuries CAUTION Notices with the word CAUTION warn about a situation that could lead to light or medium scale injuries The following symbols are used in the warnings Symbo...

Страница 11: ...sed spaces in the commercial sector Intended use also includes observing and following all instructions in these instructions especially the safety instructions Any other use is considered to be impro...

Страница 12: ...switch connector 2 Recovery key connector F 3 Recovery key connector B 4 Network connector F 5 Network connector B 6 24 Vdc connector for external power supply F 7 24 Vdc connector for external power...

Страница 13: ...Description 13 Rear View The following diagram shows the rear view of the WideTEK 36DS model No Name 1 USB connector 2 HDMI connector 3 Connector for external accessories...

Страница 14: ...twork configuration Button to drive the document forward in the scanner WHITE BALANCE Button for white balance LAMP ON OFF Button for lamp test Button to drive the document backward in the scanner rew...

Страница 15: ...JUST Button for touch adjust TOUCH TEST Button for touch test STITCH TEST Button for stitch test EMV TEST Button for EMV test SENSOR TEST Button for sensor test SHUTDOWN SCANNER Button to switch the s...

Страница 16: ...Description 16 Rating Plate The rating plate is attached to the back of the scanner The following figure shows the WideTEK 36DS rating plate...

Страница 17: ...proceed as follows Make sure that the main switch of the scanner is switched off 0 position Use only the AC adapters and power cords supplied Ensure the power cords are not damaged Connect the connec...

Страница 18: ...over To position the scanner on the optional floor stand proceed as follows Assemble the floor stand according to the floor stand assembly instructions Position the scanner on the floor stand as desc...

Страница 19: ...es can cause tripping Fractures contusions and bruises can be the result Place the connecting cables so that nobody can trip over them To connect the optional monitor proceed as follows Connect the HD...

Страница 20: ...proceed as follows Press the MAIN SWITCH 1 to the I position The scanner is in standby mode The touch panel is illuminated in a dimmed mode and shows the standby screen The standby screen shows the I...

Страница 21: ...r from standby mode proceed as follows Touch the touchscreen The touch panel lights up and a rotating hourglass indicates that the start sequence is running The scanner performs a system test After a...

Страница 22: ...rt screen screen press and hold the button STOP 1 While STOP is being held a counter in the button displays the time until the scanner is switched into standby mode Going to sleep in x seconds The sca...

Страница 23: ...Prepare for Setup 23 To switch off the scanner for longer periods proceed as follows Make sure that the scanner is in standby mode Press the MAIN SWITCH 1 in the 0 position...

Страница 24: ...reen shows the Self Test 1 screen Menu and Buttons Name SELF TEST 1 Menu name IP ADDRESS Button for network configuration Button to drive the document forward in the scanner WHITE BALANCE Button for w...

Страница 25: ...ion from the screens Self Test 1 and Self Test 2 tap with your finger on the button of the screen Assign the IP Address Manually Assign the IP Address To manually assign the IP address proceed as foll...

Страница 26: ...IP address for the back camera GATEWAY Input field for the gateway address NETMASK Input field for data on the subnet mask DHCP Assign an IP address manually or automatically SAVE Accept the network...

Страница 27: ...eft 1 and right 2 move the cursor within the chosen row The X key deletes the number at the cursor position To finalize the input tap on the CHECKMARK key The IP Address window will be closed The IP A...

Страница 28: ...TBIOS B Netbios data for the back camera WORKGROUP Workgroup name WINS Wins data NTLMv2 Use of NTLMv2 NT LAN Manager Yes No SAVE Accept the network settings provided DEFAULT Reset to factory settings...

Страница 29: ...displayed again ATTENTION The IP addresses 10 254 254 50 and 10 254 254 51 can not be used as IP network addresses for the scanner because they are already set up for the internal communication These...

Страница 30: ...ed Menu and Buttons Name ADDRESS F The IP address for the front camera ADDRESS B The IP address for the back camera GATEWAY Input field for the gateway address NETMASK Input field for data on the subn...

Страница 31: ...Setup 31 Tap the DHCP selection field and select Yes The displayed entry in the DHCP selection box changes to Yes If entries have been changed the changes must be confirmed Tap on SAVE to confirm the...

Страница 32: ...displayed again ATTENTION The IP addresses 10 254 254 50 and 10 254 254 51 can not be used as IP network addresses for the scanner because they are already set up for the internal communication These...

Страница 33: ...Perform Setup 33 Perform White Balance On the Self Test 1 screen tap on WHITE BALANCE...

Страница 34: ...Perform Setup 34 The White Balance screen is displayed Menu and Buttons Name WHITE BALANCE Menu name CONT Start white balance ABORT Abort white balance BACK Switch back to Self Test 1 menu...

Страница 35: ...the scan quality can occur if an improper test target for the white balance is used Make sure that the test target is free from wrinkles discolorations cracks or other damage Store the test target for...

Страница 36: ...med During the white balance a rotating icon appears The test target is transported forward and returned The entire white balance sequence takes about 50 seconds Then the white balance result is displ...

Страница 37: ...daylight Ensure that the test target is not damaged bent or soiled Lamp On Off This function is not relevant for setting up the device On Self Test 1 screen press the LAMP ON OFF button 4 to turn on t...

Страница 38: ...ng this function the touchscreen displays an empty area Use a suitable stylus to draw some arbitrary characters on the touchscreen Check the match between the write position and the displayed position...

Страница 39: ...function is only intended for technicians certified by Image Access and not relevant for setting up the device Sensor Test This function is not relevant for setting up the device On the Self Test 2 s...

Страница 40: ...Perform Setup 40 Paper detected by the sensor Shutdown Scanner On the Self Test 2 screen press the SHUTDOWN SCANNER button to switch the scanner to standby mode...

Страница 41: ...cale internal resolution 48 bit color internal resolution Sensor resolution 67 500 pixels 3 x 22 500 Scan modes 24 bit color 8 bit color indexed 8 bit grayscale bitonal halftone File formats Multipage...

Страница 42: ...grayscale internal resolution 48 bit color internal resolution Sensor resolution 67 500 pixels 3 x 22 500 Scan modes 24 bit color 8 bit color indexed 8 bit grayscale bitonal halftone File formats Mult...

Страница 43: ...evel VI Scanner Input voltage 2 24 Vdc Input current fused 2 max 5 A Power consumption WideTEK 36DS Sleep mode 0 5 W Standby mode ca 10 4 W Ready to scan 100 W Scanning 190 W Document specifications D...