background image

7

INSTRUCTIONS FOR THE INSTALLER

Gas. However, it can be converted for use with 

LPG. Refer to LP conversion chapter.

Supply pipe sizing

The total hourly gas consumption for the appliance 

is shown on the data label. The required supply 

pressure (i.e. at inlet to appliance regulator) for 

each gas type is shown on the data label, and 

given in page "TECHNICAL CHARACTERISTIC 

TABLES". Use this information in conjunction with 

the length of run, number of elbows, tees and 

bends, the available service pressure and the 

supply requirements of other installed appliances 

to determine a suitable pipe size. For assistance 

in this matter refer to the appropriate section of the 

Installation Code AS5601.

An AGA certified class B or D flexible connection 

may be used to connect the cooktop in accordance 

with the AS5601 and in particular section 4.8. 

Where a hose assembly is used and the cooktop 

is in the installed position, the hose assembly shall 

be suitable for connection to a fixed consumer 

piping outlet located at a point 800 - 850mm above 

the floor and in the region outside the width of the 

appliance to a distance of 250mm. The point of 

connection to consumer piping must be accessible 

with appliance installed.

Elbow positioning

It is possible to reposition the elbow if required by 

loosening the locking nut and elbow by using two 

spanners. Re-tighten the entire assembly after the 

elbow has been repositioned. When fitting elbow to 

appliance, ensure that the sealing washer is fitted.

Regulator

An appliance regulator is provided. The regulator 

must be positioned so that the pressure test nipple is 

accessible when the appliance is installed. Connect 

the gas supply to the ½” B.S.P. internal thread inlet 

of the regulator. Refer page 10 for connection point 

position.

Assembly of Regulator

The assembly of the regulator to the cooktop 

manifold is achieved via the elbow union and 

sealing washersupplied.

The ½” parallel thread connects to the manifold, and 

the sealing washer is placed between the manifold 

end and the flat face on the elbow.

The ½” tapered thread connects to the outlet of the

regulator, and is sealed on the thread using 

approved thread sealing tape or approved thread 

sealing compound.

The inlet of the regulator is a ½” parallel thread and

is connected to consumer piping or hose assembly.

Regulators are supplied pre-adjusted and 

configured by the component maker for use with 

Natural Gas.

The appliance installer is not required to make an 

adjustment to obtain the correct outlet pressure 

setting.

An arrow on the base of the regulator indicates the 

direction of gas flow when the inlet and outlet of the 

regulator is orientated correctly. When the regulator 

has been fitted check for leaks from the connections 

with soapy water.

Checking the gas supply

1.  Check the manometer zero point is correct.

2.  Connect the manometer to the cooktop 

pressure point. This is located on the 

regulator.

3.  Turn on the gas supply and electricity and try 

to ignite the gas. NOTE! lt will take additional 

time to light the gas for the first time as air 

needs to be purged from the pipes.

4.  With the appliance operating check the outlet 

pressure

• 

when all burners of the appliance are 

operating at maximum,

• 

when the smallest burner of the appliance is 

operating at minimum.

Under these conditions the outlet pressure should 

not vary from the nominal outlet pressure of 

1.00kPa by more than ± 0.20kPa

If the regulator appears to not perform 

satisfactorily, then check the following points:

1.  If the outlet pressure is consistently too low 

then the inlet pressure may be too low and 

adjustment of an upstream regulator may be 

needed, or an upstream regulator or valve 

with insufficient flow capacity may be present 

in the gas supply line. If this is suspected then 

it may be necessary to repeat fhe checks 

whilst measuring both the inlet and outlet 

pressure to determine if the inlet pressure is 

in the range 1.13 - 5kPa.

2.  Check that the regulafor has been fitted to the 

gas supply line in the correct orientation, the 

arrow on the base of the body indicates the 

direction of gas flow.

Once these checks have been completed, if the 

regulator still fails to perform in a satisfactory 

manner it should be replaced.

Electrical connection

The appliance is supplied with a standard 10 

Amp service cord terminated by a 3-pin plug for 

connection to a standard household socket. The 

electrical supply is required to power the electronic 

ignition system.

Содержание ILFM60CKX

Страница 1: ...USER MANUAL MODEL ILFM60CKX Mod 208644 13 10 2014 ...

Страница 2: ... the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent Before carrying out the maintenance or cleaning the equipment cut off power supply and allow it cool down Make sure that air circulates around the gas equipment Insufficient ventilation produces a lack of oxygen In case of an intense or prolonged use of the equipment i...

Страница 3: ...oiling All of the operating positions must be chosen between the maximum and the minimum ones never between the minimum position and the closing point The gas supply can be interrupted by turning the knob clockwise up to the closing position If there is no power supply it is possible to light the burners with matches setting the knob to the start up point large flame fig 1 BURNERS Power MJ h Ø of ...

Страница 4: ...s obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty Dry or clean ignition spark plugs Flames uneven or tending to lift Flame ports blocked or wet Clean or dry flame ports Burner incorrectly fitted Ensure this component is fitted correctly Flames not staying on when knob released Knob not...

Страница 5: ...m the electrical supply Don t use a steam cleaner for the cleaning the hob It is advisable to clean the appliance when it is cold Enamelled parts The enamelled parts must be washed with a sponge and soapy water or with a light detergent Do not use abrasive or corrosive products Do not leave substances such as lemon or tomato juice salt water vinegar coffee and milk on the enamelled surfaces for a ...

Страница 6: ...e cook top Depending on the type of mounting surface the suitable type of mounting hook is supplied hook A or hook B For the installation proceed as follows Remove all loose components from the top Turn the appliance upside down lay it s edges on foam packaging blocks to prevent damage to the ignition spark plugs and lay the seal S along the external border fig 5 Introduce and place the cook top i...

Страница 7: ...e thread using approved thread sealing tape or approved thread sealing compound The inlet of the regulator is a parallel thread and is connected to consumer piping or hose assembly Regulators are supplied pre adjusted and configured by the component maker for use with Natural Gas The appliance installer is not required to make an adjustment to obtain the correct outlet pressure setting An arrow on...

Страница 8: ...acks and burners by means of a straight spanner L unscrew the injectors U fig 7 7 A and substitute it with the corresponding one tighten the injectors strongly After changing the injectors it is necessary to eliminate residual natural gas in the system To do this you have to turn to the maximum position then press the knob of each burner and wait few seconds Adjusting the burners The lowest flame ...

Страница 9: ...9 2 1 3 4 5 7 6 8 F OFF MAXIMUM MINIMUM 9 7 A ...

Страница 10: ...ents for an extended period of time All grades of stainless steel may stain discolour or attain an adhering lajer of grime in normal operation To achieve optimum surface appearance stainless steel must be kept clean regulary using the following cleaning procedures this ensuring good performance ald long service life Wash with warm soapy water and rinse with clean water Where the stainless steel ha...

Страница 11: ...N DESCRIPTION KPa 1 100 mm 1 100 mm 2 SEMI RAPID Universal LPG 2 75 65 31 5 6 Natural 1 00 110 1 2 turn 6 3 3 AUXILIARY Universal LPG 2 75 52 27 3 4 Natural 1 00 80 1 4 turn 3 4 5 DOUBLE CROWN Universal LPG 2 75 85 60 9 6 Natural 1 00 145 Adjust 10 3 MODEL ILFM60CKX IGNITION GENERATOR TRIPOLAR TERMINAL MICRO UNIT WIRING DIAGRAM ...

Страница 12: ...luded with this cooktop is to be used for cooking vessels of diameter 120mm or smaller Correct fitment INSTRUCTIONS FOR USING THE WOK TRIVET The cast iron wok trivet included with this cooktop is to be used for cooking only the triple crow burner Correct fitment ...

Отзывы: