1
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
A
I
B
C
G
H
30” Min. *
(76.2 cm)
E
F
D
All dimensions are in inches (cm).
* Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for installation of the junction box on the
wall at the back of the cooktop.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
P/N 318201445 (0705) Rev. A
English – pages 1-5; Español – pages 6-10; Français - pages 11-15; Notes - 16
Cooktop Dimensions
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire
cable, 240/208 volt, 60 hertz, AC only electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30"
(76.2 cm).
Cooktop Cutout
Dimensions
Figure 1
WARNING
PRODUCT DIMENSIONS
MODEL
A
. WIDTH
B
. DEPTH
C
.
HEIGHT
D
.
E
. BOX WIDTH
F
. BOX DEPTH
30" Model
30¾ (78.1)
21¾ (55.2)
2¾ (7)
6½ (16.5)
28½ (72.4)
19
1
/
16
(48.4)
36" Model
36¾ (93.3)
21¾ (55.2)
2¾ (7)
6½ (16.5)
34
5
/
8
(87.9)
19
1
/
16
(48.4)
CUT OUT DIMENSIONS
G
. WIDTH
H
. DEPTH
I
. HEIGHT BELOW
MODEL
MINIMUM
MAXIMUM
MINIMUM
MAXIMUM
COOKTOP*
30" Model
29¾ (75.6)
30 (76.2)
20
3
/
8
(51.8)
20½
(52.1)
8½ (21.6)
36" Model
36 (91.4)
36¼ (92.1)
20
3
/
8
(51.8)
20½
(52.1)
8½ (21.6)
Printed in United States
IMPORTANT
: If a plywood is present in the cabinet under
the cooktop
, install the deflector supplied under the burner box
(see Fig.1-A) as shown in fig. 1-B and make a 4" X 8" (10.2 cm
x 20.3 cm) opening to route armored cable.
Note:
Remove the
deflector if the cooktop is installed over a wall oven.
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
Figure 1-A
Deflector shipping
position
Deflector position when a
plywood is present in
the cabinet
Figure 1-B