© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.
4
PLEASE READ CAREFULLY PRIOR TO INSTALLATION
INSTALLATION
PROCEDURE
When possible, have a licensed electrician or electrical expert install all
fixtures or aid in the electrical layout plans and/or diagrams prior to
installation.
Check the electrical panel to ensure proper voltage is available for the
number of fixtures installed. Panels should only support a total amperage
of 80% of its capacity. (100 amp panel should never exceed 80 amps).
1. Find a suitable location for the fixture with sufficient cooling and away
from heat sources.
2. Use the included hanging cables to hang the fixture.
3. Ensure the fixture is hung completely level to the ground. A fixture that
is not level can burn the lamp emitter incorrectly leading to shorter
lamp life, poor lamp performance and/or lamp failures.
4. Install the lamp into the roll-lock socket (instructions pages 6-7) using
soft cotton or surgical gloves.
5. Plug the power cord into the power source (electrical outlet).
6. For proper lamp break-in, we recommend that you run the fixture at
100% power for at least 100 straight hours after initial startup. This
will improve lamp life and performance.
7. Set your desired dimming ratio. NOTE: the ballast dims or raises
output gradually to protect the lamp, so you may not see an instant
increase upon changing your output percentage.
RATED VOLTAGE
208-277V
VOLTAGE RANGE +/- 10%
187-290V
FREQUENCY
50 - 60Hz
OPERATIONS FREQUENCY
140-220HZ
PERFORMANCE
REQUIREMENTS
COMPATIBILITY
Compatible with all ILUMINAR Lighting CMH DE lamps as well as the
ILUMINAR Lighting Touch & ILUMINAR Lighting HASH Environment
controllers.
© Copyright 2022, ILUMINAR Lighting
Subject to change without notice.