6.3
1
2
3
4
6.4
1
2
3
14
REPLACING A MAINS FUSE
See figure 6.2.
The mains fuse is located to the right of the dryer mains input
plug.
Switch the electrical supply off.
Remove the fuse by turning the fuseholder anti-clockwise with a
screwdriver.
Replace the fuse with one of the correct value (see section 8).
Refit the fuse by turning the fuseholder clockwise with a
screwdriver.
REPLACING A ROLLER TENSION SPRING
See figure 6.3.
Roller tension springs are fitted on the four-roller assembly only.
Springs are fitted to both ends of the roller pairs, as shown.
Switch the electrical supply off.
Press the release button and open the dryer until the lid is held
securely by the restraining arm.
Lift the four-roller assembly away.
IL893
Figure 6.2
Replacing a mains fuse