TM70Bi V3.2 (11/02)
1121174 L0.pdf
63
IKUSI reserves the right to change this information without prior notice.
ANALOGUE OUTPUT
The analogue output is connected through RL2 connector with the following signals (Imax=15mA):
Pin
Name
Function
1
VOUT
Analogue Output
2
GND
Potentiometer’s middle point
3
-V
Negative power supply (Minimun: -50V)
4
+V
Positive power supply (Maximun: 50V)
TELE-TEACHING (V3.1 OF SOFTWARE OR HIGHER VERSIONS)
Through Tele-Alignment can set the maximum and minimum values, the polarity inversion, acceleration or
deceleration ramp and curve type of the analogue output. To change to Tele-Alignment mode is necessary to
introduce a bridge in the jumper P5 (see Jumpers configuration).
Only available for TM70 consol box from
3.1 software version or higher.
+
VI
GN
CAN
TELEALIGNMENT
Relay outputs
Analogue
CAN