background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.  INTRODUCTORY REMARKS 

 

Please  read  carefully  and  follow  this  instruction. Hereinafter  you  will  find  data  on  furnace  itself  and 

instructions for its installation and maintenance.  

Furnace efficiency and safe  work depend on  its correct installation, which must be carried out by a 

professional, in compliance with applicable standards and safety regulations.  

When  choosing  a  place  to  install  the  furnace,  take  care  of  smooth  air  circulation  and  floor  and 

surrounding objects to be from fireproof materials.  

Consider  a  load  capacity  of  the  floor.  If  the  floor  can  not  bear  the  weight  of  furnace,  it  should  be 

reinforced  or  provided  with  additional  support  structure  in  consultation  with  specialists.  Also,  if  the  floor  is 
made  of  any  flammable  materials,  it  must  be  protected  by  an  insulating  plate  (from  steel,  bronze,  marbel, 
stone, etc.), extending from the front for at least  50 cm and 15 cm from the sides of furnace. (figure 1) 

Keep  sofas,  chairs,  curtains  or  other,  not  mentioned,  flammable  things  at  the  distance  of  100  cm 

from the furnace front .The side of the flammable objects must not be closer than 30cm and 30cm from the 
rear. (Figure 2) 

 

Содержание ELIPTIKO

Страница 1: ...Model ELIPTIKO USER MANUAL IKL INDUSTRIJSKI KOMBINAT LIVNICA DOO GU A Srbija 32230 Gu a Albanske spomenice bb Tel centrala 381 0 32 306 000 prodaja i servis 381 0 32 854 305...

Страница 2: ...1 Introductory remarks 2 Technical features 3 Furnace operation 4 Chimney 5 Firewood 6 Wear parts 7 Out of season instructions 8 Proceeding in case of irregularities 9 Technical description 10 Instal...

Страница 3: ...bjects to be from fireproof materials Consider a load capacity of the floor If the floor can not bear the weight of furnace it should be reinforced or provided with additional support structure in con...

Страница 4: ...vices and easily combustible substances in furnace firebox hearth or on furnace parts Prevent red heat of furnace components Do not burn any waste materials in the furnace nor use improper fuels Insta...

Страница 5: ...pressed in Dast mg Nm3 0 0891 36 Firebox door size in mm W x H 260 x 352 Firebox size W x H x D 350x258x255 Grid type Turning grid Furnace height in mm 800 with upper exhaust 860 Furnace width in mm 4...

Страница 6: ...tion smoke and odour occur emanating from the protective paint This is normal as paint only stabilizes at temperatures above 350 C IT IS NECESSARY TO VENTILATE THE ROOM Prior to firing all components...

Страница 7: ...atures For better air streaming through the chimney the latter must exceed the roof edge for at least one meter Chimney must not be sheltered by surrounding objects The chimney ensures extraction of s...

Страница 8: ...The optimum draught in the chimney is 12 Pa Measurement is to be carried out while the furnace is warm If measured draught is higher than 15 Pa it is necessary to decrease it by building in an additi...

Страница 9: ...AND DAMAGES ARISING FROM IT WILL VOID THE WARRANTY AND MANUFACTURER S LIABILITY 6 WEAR PARTS Following parts are considered wear parts which are not subject to warranty All gaskets glass components f...

Страница 10: ...condensation is normal it results from the different surrounding and furnace temperatures In case of an persisting problem check used firewood as it must not be wet nor poorly dried The chimney must n...

Страница 11: ...TALLATION The furnace needs to be connected to corresponding chimney Connection has to be possibly short straight or slightly curved up Links must be tight Honouring National and European rules and lo...

Страница 12: ...n rests ash have to be gathered in one hermetic fireproof container The furnace must not be fired in presence of any gases or steam in the atmosphere eg glue gasoline and alike Do never leave flammabl...

Страница 13: ...following materials must not be fired coal rests bark rests wet or lacquered wood plastic materials materials of organic origin otherwise the product warranty shall not apply Paper and cardboard may...

Страница 14: ...eating and damage of the furnace 15 REGULAR EXPLOITATION NOTE Out of safety reasons the firebox door may be opened while the furnace works only to refill the fuel Taking into account the large size of...

Страница 15: ...can be identified by sharp smell to overcome this situation shake the grate more often increase combustion air flow and add small quantities of fuel which will burn up faster and thus stabilize the ai...

Страница 16: ...remove ash and other residues Meanwhile check condition of gaskets and sealings In case of not satisfactory result replace them to ensure good furnace performance If there is moisture around the furna...

Страница 17: ...18 FURNACE COMPONENTS...

Страница 18: ...17 1 61 DIN 933 ISO 4017 4 11 P 410 1 37 P 318 1 62 DIN 125 ISO 7089 2 12 P 411 1 38 VS 005 1 63 DIN 125 ISO 7089 17 13 P 412 1 39 1 64 DIN 125 ISO 7089 4 14 P 413 1 40 1 65 DIN 522 ISO 4759 3 30 15 P...

Страница 19: ...angareous 20 WARRANTY The producer provides guarantee for all cast iron and steel parts The term of warranty is two years from the device purchase date providing all provisions from the manual are obs...