background image

 

Installation of the heater 

 

ELECTRICAL INSTALLATION (for certified electrician only) 

 

Beware of the sharp edges of the stainless-steel mesh. Use a long-sleeved shirt 

and protective gloves during the installation and once taking the heater out of 

the cardboard box. 

 

The electric installation may only be administered by a 

qualified electrician adhering to current regulations.  

 

1.

 

After removing the heater from the cardboard box, take off the plastic wrapping from around the 

heater. 

2.

 

Choose the place for the heater according to the required safety distances. The installation must be 

carried out in the place where the heater will be situated. The safety distances for Electric IKI 6 – 9 

kW are measured from the heater's mesh frame outwards 

(Page 12: Safety distances). 

Negligence 

to comply with the safety distances may cause fire hazard. 

3.

 

See applicable wiring diagram for the right heater model to be installed 

(Page 11),

 

ATTN! 

Heater 

must be permanently installed by using seal tight conduit between the heater and the wall of the 

sauna room (plugs are not allowed in the sauna room). All Wiring must be done by a licensed 

electrician, who must follow wiring diagram provided and adhere to local regulations. Use proper 

AWG rated wire size and use copper wire suitable for 194 °F (90 °C) within sauna walls. Make sure 

that the connecting cable will not be exposed to thermal radiation or mechanical strain. If the 

rubber cable running inside the wall of the sauna is above 1000 mm from the floor, it needs to 

endure temperatures up to 170Celsius /338Fahrenheit. The use of PVC-insulated cable as a 

connecting cable is prohibited due to thermal embrittlement. Use grounding terminals provided in 

sauna heater and control unit to properly ground the equipment as per NEC and local regulations.   

4.

 

Remove the base plate

 (Picture 1.) 

from the bottom of the connection box of the heater and 

connect the five-pole electric cable to the connection strip inside the element box according to the 

wiring diagram

 (Page 11).

 

5.

 

Once the heater is fully connected to the control unit and the house cabling, measure that all the 

heating elements function properly. If problems occur, contact the manufacturer's technical 

support

. ATTN!

 When making the final inspection of the installations, a “leakage” might be 

detected when measuring insulation resistance. The reason for this is that the insulating material of 

the heating elements has absorbed moisture from the air/ transportation. After 2 -3 times  

6.

 

Close the base plate 

(Picture 3.)

.  

7.

 

Make sure that the lower part of the stainless-steel mesh frame is fastened correctly 

(Picture 4.)

 

and that it is an equal distance from all the heating elements. Check that the heating elements 

stand up straight and install the element guidance plate appx. 15cm (6 inches) from the top of the 

elements 

(Picture 5. A: Element guidance plate).

  If they have been bent, carefully straighten them 

so that the elements go smoothly through the plate.  

8.

 

Adjust the heater to level by adjusting the heater legs. Then add the sauna stones to the heater. 

 

 

 

 

Содержание M10066NA

Страница 1: ...Instructions for installation and use IKI electric heaters with a mounted unit Pillar IKI 6 6 kW M10066NA Pillar IKI 9 kW M10090NA 2 2022 ...

Страница 2: ...1 ...

Страница 3: ...ation is complete these instructions must be given to the owner or the person caring for the sauna The sauna heater is intended for the sole purpose of heating the sauna room to a temperature appropriate for bathing Its use for any other purpose is prohibited IKI LLC Address 5621 Dupont Ave S Minneapolis MN 55419 Email ikisaunas gmail com Phone 612 801 7126 www ikikiuas com Contact information ...

Страница 4: ... ventilation 18 Gravity ventilation 19 The Sauna Room 20 WARNINGS Keep away from the heater when it is hot The stones and outer surface of the heater may burn your skin Do not throw too much water on the stones The evaporating water is boiling hot Do not let young handicapped or ill people bathe in the sauna on their own This appliance is not intended for use by persons including children with red...

Страница 5: ...ipment Do not sleep in the sauna Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 ºF The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include A Failure to perceive heat B Failure to recognize the need t...

Страница 6: ...al must be left with the owner manager or operator of the Sauna after it is tested used by an electrician The heater volume should be suitable for the sauna room volume Model table in page 11 shows the recommended sizes for each heater power output A precondition for the given values is that the sauna room is well insulated Walls and ceiling are covered with wood panels Check that supply voltage a...

Страница 7: ...e running inside the wall of the sauna is above 1000 mm from the floor it needs to endure temperatures up to 170Celsius 338Fahrenheit The use of PVC insulated cable as a connecting cable is prohibited due to thermal embrittlement Use grounding terminals provided in sauna heater and control unit to properly ground the equipment as per NEC and local regulations 4 Remove the base plate Picture 1 from...

Страница 8: ...any point during the adding of stones Picture 11 You can leave the element guidance plate plate under the stones appx 15cm 6 inches from the top of the heating elements Do not drop stones into the heater at any point instead pile them carefully Be especially careful with the corners where the heating elements are near the mesh to cover the area between the elements and mesh A bare heating element ...

Страница 9: ...8 2 1 4 3 6 5 ...

Страница 10: ...9 12 11 8 7 10 9 ...

Страница 11: ...10 14 13 16 15 ...

Страница 12: ...t 3 Timer 4 Heating elements 5 Ground 6 Overheating limit control Supply wires Heater model Input kW Voltage Amps Circuit breaker A Wire Size AWG Pillar IKI 6 6 6 6 240 28 75 30 10 Pillar IKI 9 9 240 37 5 40 6 All supply wire to be 90 C copper ...

Страница 13: ...b 6 6 kW Pillar IKI 9 kW 282 565 ft 43 3 110 cm 13 4 34 cm 130 kg 286 lb 9 kW Safety distances Safety distances to inflammable materials such as wall paneling and sauna benches A Pillar IKI 6 6 kW 4 inches 10 cm Pillar IKI 9 kW 4 inches 10 cm B Pillar IKI 6 6 kW 35 4 inches 90 cm Pillar IKI 9 kW 35 4 inches 90 cm Supporting the heater against a wall ...

Страница 14: ...tion for maximum 1 hr The heater has 8 1hr timer That means that you can set the heater to begin heating after a delay of up to 8hrs If you tun on the heater to 1 9hr zone the heating will start automatically after the selected delay time has elapsed High temperature control reset button The heater has a build in high limit control which automatically will turn off the heater if the temperature ri...

Страница 15: ...ter You can adjust the feel of the heat and steam from soft to sharp by throwing water either to the side of the heater or by pouring water on top of the stones at different places Check that the heating elements do not become exposed as the stones shift about due to heat expansion The stones settle normally in the first 10 20 times when heater is used Check the condition of the stones at least on...

Страница 16: ...the stones not water goes through without generating steam Turn the temperature lower from the controller Check that the heater output is not too high Page 12 Model table Check that the heater output is not too high Page 12 Model table Check that the sauna room ventilation has been arranged correctly If the wood panel starts to darken around the heater Check that the requirements for safety distan...

Страница 17: ... installation of the replacement part must be carried out by an licensed electrician The guarantee does not cover the faulty part removal or repair costs on the field If the heater is returned to the manufacturer or retailer within 2 years from the date of purchase the importer will provide free repair work but may charge for spare parts if the warranty period has expired The guarantee is void if ...

Страница 18: ...ne fractures characteristic to natural stones which do not affect the use or the safety of the heater Damages occurred during shipping must be recorded in the waybill when the product is received or within 7 days of delivery Shipping damage must also always be reported to the shipping company s last contact The damaged part needs to be stored for inspection Insurance compensates for the new part w...

Страница 19: ... the heater The supply air inlet vent should be 2 4 inches 50 100 mm in diameter The outlet vent should be located as far away from the heater as possible close to the floor The outlet vent should be twice the size of the inlet vent NOTE The sensor for the thermostat should be located at a minimum of 39 inches 1000 mm distance from undirected vent for replacement air or minimum of 20 inches 500 mm...

Страница 20: ...19 Gravity ventilation ...

Страница 21: ...um height 75 1900 mm As a result the volume of the sauna is decreased and a smaller heater output may be sufficient The ceiling can be lowered so that the ceiling joists are fixed at a suitable height The spaces between the joists are insulated minimum insulation 4 100 mm and surfaced as described above Because heat goes upwards a maximum distance of 47 1200 mm is recommended between the bench and...

Страница 22: ...ut When the walls and ceiling are covered with panels and the insulation behind the panels is sufficient to prevent thermal flow into the wall materials the heater output is defined according to the cubic volume of the sauna Because log walls are heated slowly the cubic volume of a log sauna should be multiplied by 1 5 and the heater output should then be selected on the basis of this information ...

Страница 23: ...22 ...

Страница 24: ...23 Copyright IKI LLC We reserve the right to changes ...