Other possible problems are:
The control unit is working fine, but the heater does not turn on. Check the
electricity supply to the heater. Check that the wires for the sensors are placed into
the correct terminals in the control unit.
If heater doesn’t heat up check that set temperature is set to higher temperature
than current sauna room temperature.
If wooden parts of sauna get dark fast, check safety distances and loading of
stones.
Heater doesn’t turn on and main switch is in “ON” position. Check following:
User presses a button and “----“ is shown in the display. This indicates that the key
pad is locked. Unlock the buttons by pressing up and down arrow keys at the same
time for more than 5 seconds. A high beep will confirm the activation and the
deactivation.
Valtuutettu ammattimies tekee
kytkennät ja korjaukset.
Wiring and repairs must be
done by a certified electrician.
Älä käytä kiuasta grillinä.
Do not use the heater as a grill.
Älä laita puita sähkökiukaalle.
Do not put wood of any kind
on the electric heater.
Älä peitä kiuasta. Se aiheuttaa
palovaaran.
Do not cover the heater. It may
cause a fire.
Älä kuivata vaatteita kiukaalla.
Se aiheuttaa palovaaran.
Do not use the heater as clothes
dryer. It may cause fire.
Älä istu kiukaalla. Se on todella
kuuma ja aiheuttaa palovammoja.
Never sit on the heater. It is really
hot and can cause serious burns.
Älä koskaan käytä kiuasta ilman
kiviä. Se aiheuttaa palovaaran.
Never use the heater without
stones. It may cause a fire.
Älä käytä kloorivettä (esim. Uima-
tai porealtaasta) tai merivettä. Se
tuhoaa kiukaan.
Do not use chlorinated water (e.G.
From the swimming pool or jacuzzi)
or seawater. It can destroy the
heater.
Door open symbol is displayed with high warning tone, when door sensor is not
installed. - Check that door switch terminals are connected with each other by wire
in the power controller. (See fig. 2/Sensors. Note that the connections is not pres-
ent in the drawing.
This heater manual will be given to the owner of the heater after
installation.
- Terminals N2in and N are interconnected with a jumper wire
- Fuse F1 is tightly placed in fuse holder.
- Main fuses/circuit breakers are OK
Turvaohjeet
Heater Precautions