SUOMI / ENGLISH
17
Warning
Temperature sensor 1 is
not connected.
Check the wire between the sensor and
the control unit. If there is no problem
with the wires and they are correctly
installed, check the sensor.
If no reason for the problem can be found,
contact the retailer.
E1
Temperature fuse is
defective.
Check the wire between the sensor and
the control unit. It has probably over-
heated. The reason for it needs to be
discovered before using the sauna again.
A new sensor is needed.
If no reason for the problem can be found,
contact the retailer.
E3
Temperature sensor 1
is short circuit.
E2
Temperature sensor 2
is not connected.
Check the wire between the bench sensor
and the control unit. If there is no problem
with the wires and they are correctly
installed, check the sensor. The heater can
still be used with the sensor 1 only, but 2
sensors are needed for the steamer.
If a new sensor is needed or no reason for
the problem can be found, contact the
retailer.
E4
Temperature sensor 2
is short circuit.
E5
Communication failure.
Check the RJ12 cable. If the area where
the cable is located has many other cables,
it can cause interference problems. If
built-in model is used, remove the control
panel. Wipe the pin header contact to
remove any dirt. Assemble back the
control panel in correct position and make
sure the six pin header connectors are
properly inserted to the socket.
If no reason for the problem can be found,
contact the retailer.
E7
Code
Problem
Solution
Combined Temperature
/ Humidity sensor is defective.
E6
Temperature is greater
than the maximum
temperature.
If this happens contact qualified electrician
or maintenance personnel before using
the sauna again.
E8
Troubleshooting
If an error occurs, the heater will be
switched off. There will be a warning
beep and the code for the error will
be displayed in the control panel.
See more details on the table below.
Please note, only a qualified electrician or
maintenance personnel is allowed to make the