Ikelite 6951.07 Скачать руководство пользователя страница 8

- Insert a fully charged camera battery and a SD card. 
- Set Mode Dial to “Av” Aperture Priority. Set aperture to F5.6, or F18 for

macro photography (close-ups). If faster shutter speeds are desired or a
DS-series strobe is not being used, then set Mode Dial to “M” Manual
Mode and shutter speed to 1/60th second or 1/125th second for fast
moving subjects. Other shooting modes are not recommended.

-

In       1 Menu:
Caution:

Save recorded images on the SD card to a computer or other

device before formatting card. In Card Setup, set Format to “Yes.”
In Record Mode set Still Picture to LF or other desired setting. Set Movie
to “MOV to FullHD       F.”

-

In       2 MENU 

set Image Stabilizer (Still Picture) to “S-IS-AUTO.”

-

In A. Custom MENU: 

Set AF Mode Still Pictures to “S-AF.”

Set Full-time AF to “Off.” Set Reset Lens to “Off.” 
Set Home A. AF/MF to the center. Set AF Illuminat. to “Off.”
Set Face Priority to “Off” and Area Pointer to “on.”

-

In F.      Custom Menu: 

set X-Sync. to 1/250 and Slow Limit to 1/60.

-

In J. Custom Menu: 

Set Touch Screen Settings to “Off.”

-

In     MENU: 

Set Rec View to “4sec.”

-

In OK Menu: 

Set White Balance to “Auto.” For best results, set to Manual        White
Balance and reset for each working depth or when using a color filter.
Set Aspect Ratio to “4:3” or other desired setting.
Set Flash to “Fill In     .”     
Set Metering to “Ctr-weighted       ” and ISO to “200.”
Set Face and Eye Priority to “Off.”

* All camera functions not mentioned should be set to the user preference. 

STEP 2 - Initial Camera Settings 

Setup your camera for underwater use and then adjust your settings once underwater.

8

1

Содержание 6951.07

Страница 1: ...c t i o n M a n u a l MADE IN USA Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product Please refer t...

Страница 2: ...talling Camera in the Housing P 9 11 STEP 5 Attach the Hotshoe P 12 STEP 6 Closing the Housing P 12 STEP 7 Attach Optional MIL Port P 13 STEP 8 Final Check P 13 Usage P 13 Entering the Water P 14 Remo...

Страница 3: ...oroughly inspect and immerse the empty housing completely in water before installing a camera If any fogging occurs or droplets of water enter the housing do not install a camera Clean the main housin...

Страница 4: ...in Flash No Tray and Handle Weight 11 5 oz 327 g Main O Ring 0110 Housing Dimensions 6 4 x 7 5 x 5 9 in 163 x 190 x 150 mm Housing Weight 3 19 lb 1447 g not including tray handles or port Housing Mate...

Страница 5: ...using Front View Shutter Button Lens Port Base External Tray Mounts Lid Snap Mode Dial ON OFF Button External Strobe Connector Cap Lens Release Button Housing controls are provided for all accessible...

Страница 6: ...Control Dial 2 Fn Button 3 Button 4 Movie Button 5 MENU Button 6 INFO Button 7 Up Exp Comp Button 8 Left AF Target Button 9 OK Button 10 Right Flash Button 11 Down Self timer Button 12 Erase Button 1...

Страница 7: ...possible to avoid accidentally scratching table tops or other surfaces with the Tray Mounting Bolts To remove loosen both 3 8 16 Nuts using a 9 16 open box end or socket Wrench not supplied MADE IN U...

Страница 8: ...till Picture to S IS AUTO In A Custom MENU Set AF Mode Still Pictures to S AF Set Full time AF to Off Set Reset Lens to Off Set Home A AF MF to the center Set AF Illuminat to Off Set Face Priority to...

Страница 9: ...Snap Tab to break the housing seal Push Forward Lid Snap Lock Lift 1 Make sure the camera battery is fully charged and a SD card is inserted into the camera 2 Rotate Housing Lens Release Button contr...

Страница 10: ...attachment to a land tripod stand Diagram B Tray Removal Screw Mounting Tray 5 Gently slide the camera with Mounting Tray back into the Mounting Plate with the camera attached Diagram C page 11 Make s...

Страница 11: ...all the way forward into the Mounting Plate Diagram C Mounting Plate Mounting Tray STEP 4 Installing Camera in the Housing continued Port Base Port Base O ring 11 Hotshoe Wire Hotshoe pushed all the...

Страница 12: ...nded and place each lid snap into the corresponding hook on the housing back 4 To close the housing push down on the opposing lid snaps simultaneously until they snap into place Be sure they are down...

Страница 13: ...eal M I L MIL Mirrorless Interchangeable Lens 13 STEP 8 Final Check The clear housing permits instant visual inspection of the camera and sealing surfaces as well as complete monitoring of controls an...

Страница 14: ...Remove the Hotshoe from the camera mount 4 Place your index finger over the top of the Tray Removal Screw and gently pull backward to separate Mounting Tray and camera from housing Continue pulling Mo...

Страница 15: ...exposure when used with Ikelite DS series strobes The Circuitry is automatically activated once a DS series strobe is attached to the housing and turned on Once attached turn the strobe on first befo...

Страница 16: ...is installation If the Sync Cord does not seat properly inside the Bulkhead then the Pins and Receptacles are improperly aligned repeat Step 3 4 Tighten the Knurled Nut snugly using your Index finger...

Страница 17: ...y slide the pronged end of the Ikelite Arm into the hole in the top of the Handle as shown Diagram G When the Ikelite Arm is properly seated the Handle Push Button will return to its starting position...

Страница 18: ...MIL Mirrorless Interchangeable Lens Ports A full range of accessories are available to support your housing Please visit www ikelite com to see the most current information about recommended accessor...

Страница 19: ...tion Excessive lubricant can collect sand hair and dirt which may interfere with proper sealing CAUTION Never use spray lubricants as the propellant ingredient can cause the plastic housing to crack o...

Страница 20: ...o ring to lubricate do not use metal objects that may scratch the o ring sealing surface Only apply enough lubricant to make the o ring feel slick Do not stretch the o ring This light coating of lubri...

Страница 21: ...n If this does not correct the problem return the housing to Ikelite for maintenance If you are on a trip and unable to return the housing immediately a push button may be lubricated by pressing and h...

Страница 22: ...len wrench required remove the knob If there is salt or dirt build up on the exposed control shaft clean the shaft Open the housing and gently slide the control shaft out of the control gland Clean an...

Страница 23: ...hoot down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue water as a co...

Страница 24: ...icky grab the control knob pull it out and then push back in If still sticky see the Control Maintenance section Diagram I Page 22 Camera eyecup must be removed Return housing to Ikelite for routine m...

Страница 25: ...port Close the housing in an air conditioned room or vehicle or in front of an air conditioner The housing should not be in direct sunlight for an extended period of time Purchase desiccant packs als...

Страница 26: ...Add an optional color correcting filter to the camera lens Use custom manual white balance Reset for each working depth or when attaching a color correcting filter to the camera lens Add an external s...

Страница 27: ...manufacturer for repair service Value of the equipment listed for customs purposes should be zero Returning Products for Service outside the United States Ikelite is most interested in performing any...

Страница 28: ...West 33rd Street Indianapolis IN 46208 USA www ikelite com Product Registration Please go to www ikelite com to register your Ikelite housing within 15 days of purchase 6951 07_Olympus_E PL7_02 0215 2...

Отзывы: