Control Maintenance 

Ikelite controls are designed to provide years of reliable service with
minimal maintenance.

-

Push button controls require no maintenance other than rinsing in fresh
water after saltwater use. If a push button control becomes difficult to
push or if it sticks when depressed, soak the housing in luke warm fresh
water. After a few minutes, operate the push button. If this does not
correct the problem, return the housing to Ikelite for maintenance.

-

Some of the controls have long shafts. These controls can be pulled out,
exposing the shaft, diagram B, page 24. 
To lubricate the control, gently pull on the knob until the stainless steel
shaft is exposed. Lightly lubricate the shaft, then move the shaft in and
out several times. This will lubricate the x-ring in the Ikelite control gland.
This should be done before using the housing after a prolonged storage
period, or once a week when the housing is in constant use.

-

Some of the controls have a short shaft and cannot be pulled out
exposing the shaft for lubrication. In the unlikely event one of these
controls sticks or becomes difficult to operate you can remove the
control from the housing and lubricate it, or return the housing to Ikelite
for maintenance. To remove the control, diagram A, page 24, loosen the
set screw in the knob (allen wrench required); remove the knob. If there
is salt or dirt build-up on the exposed control shaft, clean the shaft.
Open the housing and gently slide the control shaft out of the control
gland. Clean and lightly lubricate the shaft, including the end of the
shaft.  Slide the shaft back into the control gland and gently slide it back
and forth a few times without fully removing the shaft from the gland.
Replace the knob noting the flat area on the shaft. The set screw in the
knob should tighten down against the flat area on the control, so the
knob does not turn on the shaft.

Maintenance

Содержание 6812.7

Страница 1: ...Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product SLR DC Housing i n s t r u c t i o n m a n u a l...

Страница 2: ...Closing the Housing P 9 Installing Zoom Clamp and Gear Sleeve P 10 Installing the Port P 15 Housing Conversion Circuitry P 17 Flash Dial DS50 and DS125 Substrobe Compatibility P 18 Using Non Ikelite o...

Страница 3: ...ly in water before installing a camera If any fogging occurs or droplets of water enter the housing do not install a camera Clean the housing main o ring and retest to make sure that it is watertight...

Страница 4: ...Gear Sub command Dial Fn Button Shutter Release Lid Snap Side View Gear Sleeve Optional Port Port O ring Main Housing O ring Camera Tray Camera Mounting Bolt Aluminum Tray Mode Power Switch Fn Button...

Страница 5: ...2 Multi selector 13 Center of Multi selector 14 Multi selector 15 Flash Compensation 16 Multi Selector 17 AF Area Mode Selector 18 Info Quick Settings Width 10 in 250mm including controls 13 7 in 348m...

Страница 6: ...ecommended Set the shooting mode to M manual Set Date and Time Set shutter speed to 1 60th second or 1 125th second for fast moving subjects Maximum shutter speed of 1 250th second recommended to allo...

Страница 7: ...st the tray The Leveling Screw is factory preset and does not need to be adjusted Setting the Conversion Circuitry Strobe ID Switch Inside the housing back on the black panel the conversion circuitry...

Страница 8: ...camera is secured with the mounting bolt Caution Do not remove the External Strobe Connector s waterproof cap unless an external sync cord is going to be plugged in Do not remove waterproof cap or syn...

Страница 9: ...ey snap into place Lid snaps on opposite sides of the housing should be closed at the same time Be sure they are down far enough to engage the lid snap lock Double check Once the housing is closed che...

Страница 10: ...Start with the suggested Zoom Clamp and Gear Sleeve depending on the Type of lens being used See Fig A or B lens opening zoom ring bayonet mount Type 1 lens Type 2 lens Figure 1 Figure 2 Normally use...

Страница 11: ...the rubber strips supplied to the inside diameter of the Zoom Clamp as shown in figure F page 12 Two thicknesses of rubber strips are provided Start by installing the thinnest rubber strips If the Zoo...

Страница 12: ...12 Figure D Figure E Align Ribs with Zoom Clamp grooved tabs apply rubber strips to inside of clamp Figure F Type 1 Lenses cont Gear Sleeve Ribs...

Страница 13: ...the housing Place the Gear Sleeve in the housing opening as shown Install the black Zoom Clamp on the Lens Zoom Ring and lower the lens into the housing opening Make sure the Zoom Clamp grooved tabs...

Страница 14: ...result in loss of zoom capability 14 Installing Zoom Clamp Sleeve on Type 2 Lenses cont Before installing the lens port and checking operation make sure the teeth on the Gear Sleeve mesh with the tee...

Страница 15: ...Place the port with o ring into the housing port opening Press down on the port firmly and evenly until you feel the port slide into place Continue to push down on the port and push each port lock fo...

Страница 16: ...he port turn the Zoom Control knob on the housing If the Zoom Control is difficult to turn the gear sleeve may be warped If necessary reduce or omit any rubber installed on the Zoom Clamp figure F pag...

Страница 17: ...trobe for a dust cap which may not be waterproof See page 18 for DS50 and DS125 Substrobe compatibility with the Conversion Circuitry Using the Conversion Circuitry Set DS Substrobe to TTL mode Mode a...

Страница 18: ...Number between 63 850 and 69 999 require upgrade of electronics to operate Cost of update depends on strobe circuitry Strobe must be returned to Ikelite for evaluation to provide an estimate of upgra...

Страница 19: ...th the housing We recommend that you use only Ikelite lubricant Other brands may cause the o ring to swell and not seal properly Use only enough Ikelite lubricant to lightly cover control shafts and o...

Страница 20: ...ticky see the Control Maintenance section pages 23 24 Return housing to Ikelite for routine maintenance Problem Solution Image is over or under exposed Check that the strobe s are firing when taking a...

Страница 21: ...an air conditioned room or vehicle or in front of an air conditioner The housing should not be in direct sunlight for an extended period of time Purchase desiccant packs from a local camera store and...

Страница 22: ...asher for 12 24 Screw 9104 5 Waterproof Bulkhead Cap 0200 91 Body Cap Accessory Mounting Points The top of the SLR DC housing features a 1 4 20 threaded mounting point for the attachment of a focus li...

Страница 23: ...ng after a prolonged storage period or once a week when the housing is in constant use Some of the controls have a short shaft and cannot be pulled out exposing the shaft for lubrication In the unlike...

Страница 24: ...out to expose shaft Diagram B Loosen set screw allen wrench required Tighten set screw down against this flat area when replacing the knob Housing Gland Control Shaft Lubricate end of shaft before re...

Страница 25: ...lkelite lubricant on your fingers Pull the o ring through your fingers to apply a light coating of lubricant Only apply enough lubricant to make the o ring feel slick Do Not stretch the o ring This l...

Страница 26: ...Do not shoot down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue wate...

Страница 27: ...her claims of any nature are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product Storing the Housing When the housing is going to be stored for...

Страница 28: ...Service Ikelite is most interested in performing any service to ensure that all products perform as intended Evidence of purchase date must be provided to obtain warranty service No prior authorizati...

Отзывы: