- 16 -
4-4. Description of MENU 2 Functions
1 .FU NCT ION 1 M ODE
WFM
2 .FU NCT ION 2 M ODE
VIT C
3 .RE MOT E N O.
01
4 .CH ANG E A SP ECT
AUT O
5 .BA CKL IGH T DIM .
1 0
6 .TA LLY
R/G
7 .RE AL SCA N
OFF
8 .SD I C H L OC K
OFF
9 .FO RMA T D IS PLA Y
ON
M ENU 2(MO DE)
S ET→ EXIT →
ESC
ENT
① Setting the function assignment of F1 switch
④ Setting the automatic/manual aspect ratio change
③ Setting the serial remote control ID number
⑤ Setting the backlight brightness level
⑥ Setting the tally lamp indication
⑦ Setting the same-size (dot-by-dot) display ON/OFF
⑧ Setting the SDI channel switching lock ON/OFF
⑨ Setting the format display ON/OFF
② Setting the function assignment of F2 switch
①
Setting the function assignment of F1 switch
Set any of the following operations performed by
pressing the
F1
switch on the front panel.
< Assignment list of the
F1
and
F2
switches >
• FILE
(Preset file change)
• MRK SEL (Marker type change)
• COMB
(Decoder Y/C separation setting change)
• CHR UP
(Chroma up ON/OFF change)
• IP MODE (IP conversion mode FIELD/FRAME
change)
• DELAY
(Delay H/V/H+V change)
• RS ON
(Same-size display ON/OFF change)
• USR MRK (USER MARKER display ON/OFF
change)
• VSC ON
(VECTOR display ON/OFF change)
• VITC ON (SDI VITC display ON/OFF change)
• WFM ON (WFM display ON/OFF change)
• PC SEL
(CM-240: PC/COMP. input change)
• SYNC
(CM-240: SYNC INT/EXT change)
• AUD CH
(Channel change of embedded audio)
• BL DIM
(Backlight brightness level change)
* PC SEL and SYNC are selectable only when the
CM-140 (option) is mounted.
* DELAY is not operative with PC, DVI(PC) and
VBS signals. When set at DELAY, the same-size
(dot by dot) display is fixed in order to prevent
any scaling process.
• Default setting is WFM ON.
②
Setting the function assignment of F2 switch
The function assignment is selectable in the same
way as that shown above
①
by pressing the
F2
switch on the front panel.
• Default setting is VITC ON.
③
Setting the serial remote control ID number
Used to set the ID number (01 to 99) of the monitor.
The ID number is assigned to each monitor in order
to perform remote operation with the serial remote
controller (SRC-301A/Z).
• Default setting is 01.
④
Setting the automatic/manual aspect ratio change
Used to select the automatic setting of a preset
aspect ratio or the fixed setting for all reception
channels, when selecting any reception channel.
• AUTO
: displayed with the set aspect ratio
for each channel
• MANUAL : displayed with the same aspect ratio
for all channels
• Default setting is AUTO.
* When making an aspect change in the parallel
remote mode, set to “MANUAL”.
⑤
Setting the backlight brightness level
Set the backlight brightness in 1 to 30 steps.
When the backlight brightness level is raised,
the black level is also slightly raised. Therefore
set the backlight brightness level according to
the ambient condition.
This function can be assigned with the
F1
F2
switch on the front panel.
• Default setting is 10.
* The use at lower backlight brightness level