- 15 -
4-3
.
Descr
i
pt
i
on of MENU 1 Funct
i
ons
* Note the following description on the menu.
The vertical frequency “/60” includes both 60 Hz and 59.94 Hz (60/1.001).
The vertical frequency “/48” includes both 24 psF and 23.98 psF (24/1.001) in SF mode.
The vertical frequency “/24” includes both 24 Hz and 23.98 Hz (24/1.001).
1 .VBS FO RMAT
2 . → Y/C SEP.
2D YCS
3 . → NTSC SET UP LVL
0%
4 .DVI FO RMAT
5 . → YPbP r/RG B
Y P bPr
6 .COM P. FORM AT
7 . → YPbP r
Y P bPr
8 . → 1035 / 1080 i
1 0 8 0 i
9 . → 480 i S ETUP LV L
0 %
10.S YNC
IN T
M ENU 1(FO RMAT ):10 80i
SET→ E XIT →
ESC
ENT
② Setting the decoder Y/C separation
⑥ CM-240: Setting the line format with COMP. inputs
④ Setting the YPbPr/RGB signal format of DVI inputs
① Format display of selected signal
③ Setting the NTSC setup level
⑦ CM-240: Setting the 4801i format setup level
⑧ CM-240: Setting SYNC INT/EXT
⑤ CM-240: Setting the YPbPr/RGB signal format
(The dashed-line-boxed items are effective with the CM-240 mounted.)
①
Format d
i
splay of selected s
i
gnal
Shows the format of the currently selected signal.
②
Sett
i
ng the decoder Y/C separat
i
on
For the Y/C separation of VBS (composite) signals,
set any of the following three types of formats.
• 2DYCS: two-dimensional comb filter
• 3DYCS: three-dimensional comb filter
• TRAP : trap filter
This function can be assigned with the
F1
F2
switch on the front panel.
• Default setting is 2DYCS.
③
Sett
i
ng the NTSC setup level
Used to set the setup level at the time of NTSC
signal input. When the black level of the signal
has 7.5% setup, it is set to "7.5%".
• Default setting is 0%.
④
Sett
i
ng the YPbPr/RGB s
i
gnal format of DVI
i
nputs
Used to set the DVI input signal format to
YPbPr or RGB.
• Default setting is YPbPr.
⑤
CM-240
:
Sett
i
ng the YPbPr/RGB s
i
gnal format
Used to set the component input signal format to
YPbPr or RGB when the optional CM-240 is
mounted.
• Default setting is YPbPr.
* This item is selectable only when the CM-240
(option) is mounted.
⑥
CM-240
:
Sett
i
ng the l
i
ne format w
i
th COMP
.
i
nputs
Used to set the component signal to “1035i” only
in the 1035i/60 format input when the optional
CM-240 is mounted.
• Default setting is 1080i/60.
* This item is selectable only when the CM-240
(option) is mounted.
⑦
CM-240
:
Sett
i
ng the 480
i
format setup level
Used to set the component signal setup level in
the 480i/60 format input when the optional CM-
240 is mounted. When the black level of the
signal has 7.5% setup, it is set to “7.5%”.
• Default setting is 0%.
* This item is selectable only when the CM-240
(option) is mounted.
⑧
CM-240
:
Sett
i
ng SYNC INT/EXT
With the YPbPr/RGB signal input, set the use of
a sync signal that is separated from the Y or G
on SYNC image signal or the use of a sync signal
that is externally inputted.
This function can be assigned with the
F1
F2
switch on the front panel.
• Default setting is INT.
* This item is selectable only when the CM-240
(option) is mounted.
Содержание HLM-3250W
Страница 1: ...MODEL HLM 3250W FULL HD MULTI FORMAT LCD COLOR MONITOR OPERATION MANUAL ...
Страница 2: ......
Страница 57: ... 48 Thread depth to be below 12 mm including the opposite side Accessories 6 pieces 11 External View ...