background image

3 - 12       3.  INSTALLATION AND CONNECTION

BS-79

BS-79  0212  VOL1  (U) (E)

• 1730/1731

RGB  STAIR

RGB  ENABLE

1 LIN / 1 FLD

REMOTE  SYNC  ENABLE

RECALL 2

RECALL 3

RECALL 1

RECALL 4

GND

REMOTE  SYNC  IN

STORE

PRESET 4

PRESET 1

PRESET 2

PRESET 3

DA - 15P : JAE  or  AMP
DA - CI - J10 - 36 (HOOD) : JAE
or  206471-1 (HOOD) : AMP

WFM  REMOTE

FUNCTION

No.

A

B

C

D

E

F

G

STAIR  OUT

SEQ  ON

NC

-15 V (-) IN

GND

EXPAND

-15 V (+) IN

1730  WFM

FUNCTION

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

PRC03 - 12A10 - 7M10.5

• 1740/1741/1750/1751

GND

CHROMA  FILTER

LOW  PASS  FILTER

2  LINE (2H)

+V

EXT  BLANK

WFM  SEL

REMOTE  SYNC

GND

REMOTE  SYNC  ENABLE

VECTOR

SCH

REMOTE  ENABLE

CH  B

CAL

DC  RECT

MAG

EXT  REF

RGB  STAIR  CASE

-12 V

1 FLD

X5  VERT

R - Y (V  AXIS) SEL

1 LINE (1H)

RGB  ENABLE

DB - 25S - N
DB - C2 - J9 - S6 (HOOD)
(DB - 25P)

1740  FUNCTION

SPARE 1

SPARE 2

SPARE 3

SPARE 4

REMOTE  ENABLE

WFM  REMOTE

FUNCTION

No.

A

B

C

D

E

F

G

STAIR  OUT

SEQ  ON

NC

-15 V (-) IN

GND

EXPAND

-15 V (+) IN

1740  WFM

FUNCTION

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

PRC03 - 12A10 - 7M10.5

Содержание BS-79

Страница 1: ...BS 79 BASE STATION OPERATION MANUAL 0212 1st Edition U E...

Страница 2: ...pyright 2002 Ikegami Tsushinki Co LTD We reserve the copyright on the software we create No portion of this publication may be reproduced in any form or by any means without prior written permission f...

Страница 3: ...ipment turn off the POWER switch of BS 79 and that of the peripheral equipment and then connect it using a dedicated cable 4 Do not drop the equipment or subject it to strong shock or vibration 5 Avoi...

Страница 4: ...nnectors 3 7 3 7 Mounting a Rack Mount Adapter 3 17 4 SETTINGS 4 1 4 1 BS Menus 4 1 1 Menu operation procedure 4 1 2 BS menus 4 2 3 BARS TITLE function 4 4 4 2 Setting the Operating Mode with more tha...

Страница 5: ...function There are three types of modes side panel mode squeeze mode and letter box Choice of external synchronization signal You can select 525 59 94 BBS or 1080 59 94 PS S as the external synchroni...

Страница 6: ...Reference phase signal SYNC 0 6 Vp p 75 ohms one line 12 Output signals NTSC system Composite video signal VBS 1 0 Vp p 75 ohms two lines when the down converter is installed Component signals R G B 0...

Страница 7: ...AWB ABB SKIN DTL COLOR TEMP AHD AUTO HUE DETECT CALL Automatic functions AWB ABB IRIS AUTO SET UP RGB BLK SET RGB GAIN RGB FLARE RGB GAMMA RGB PEDESTAL MASTER PEDESTAL RGB BLK SHADE RGB WHT SHADE Envi...

Страница 8: ...1 4 1 OVERVIEW BS 79 BS 79 0212 VOL1 U E 1 4 External View 430 5 5 218 5 5 160 5 5 1 1 1 2 2...

Страница 9: ...MIC switch Turns the intercom microphone on or off When the microphone is on conversation is enabled 6 INTERCOM connector Connects an intercom headset The connector differs depending on the specifica...

Страница 10: ...GENLOCK indicator HD H PHASE COARSE control HD H PHASE FINE control SD H PHASE COARSE control SD H PHASE FINE control 1 2 3 4 5 6 7 8 9 SD SC PHASE COARSE control SD SC PHASE FINE control LOCAL REMOT...

Страница 11: ...C SC phase coarse adjustment Can be used only when the LOCAL REM switch 12 is in the LOCAL position 11 SD SC PHASE FINE control Adjusts the NTSC SC phase fine adjustment Can be used only when the LOCA...

Страница 12: ...nector ENC OUT connectors MCP CCP connector OCP CCP connector HD SDI OUT connectors 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RET IN connectors SYNC OUT connector D1 OUT connectors GENLOCK IN connectors PS S I...

Страница 13: ...control panel connected to this connector does not operate To operate the control panel remove the RCP 50 from the front panel of the BS or set the RCP ON OFF switch to OFF see Section 2 2 Inside of t...

Страница 14: ...CONNECTION 3 1 System Setup Diagram AC IN DC IN Headsets PROD ENG OCP CSU MCP Cable Max 30m CP Cable Max 300m CP Cable Max 300m HDK 79D E Headset PM WFM Coaxial Cable WFM Cont Cable MCP MIC 1 FA 79 B...

Страница 15: ...tandard operation PM or WFM WFM REMOTE PM WFM BS 79 RCP 50 AC IN DC IN HDK 79D E FA 79 Example 2 Remote operation PM WFM WFM REMOTE OCP CCP PM WFM BS 79 RBK 79 AC IN HDK 79D E FA 79 OCP RCP 50 with XR...

Страница 16: ...BS 79 RBK 79 AC IN AC IN HDK 79D E FA 79 OCP OUT CSU 1 CSU 2 CSU 3 CSU 4 CSU 5 PM WFM WFM CONT COMM MCP IN BS 1 BS 8 WFM PM PM WFM MCP CCP BS 8 PM WFM BS 1 OUT IN BS 16 BS 16 BS 9 BS 9 WFM PM OUT IN...

Страница 17: ...2 VOL1 U E 3 3 Device Connection Diagram PM WFM Iris remote controller WFM Cont Cable Max 5m CP Cable Max 300m CP Cable Max 300m Coaxial Cable Max 50m 5C 2V Coaxial Cable Max 50m 5C 2V Remote Cable AC...

Страница 18: ...ntroller To connect a device such as an iris remote controller to the REMOTE connector on the back of the BS 79 an RCP 50 must be mounted as the BS front panel Set the items to be controlled by the re...

Страница 19: ...Secure the RBK 79 on the front of the BS 79 with two screws Be careful that the cable does not get caught between the panels RCP joint cable AUDIO module 16p 14p 10p12p Tighten the two screws BS 79 RB...

Страница 20: ...side Pin Number Name Function Direction External Interface Receptacle CAMERA connector 3K series SMPTE 30H type 3 4 01 02 1 2 3 4 OPT H B OPT B H MTL H B H MTL C H B DC 160V H DC 160V C Optical conta...

Страница 21: ...nnector is used to connect a camera head to the BS BS side OPS PR Tajimi Cable side OPS J or equivalent Insertion side Pin Number Name Function Direction External Interface Receptacle 1 3 01 02 2 4 Gu...

Страница 22: ...data OCP CCP RM BUSY signal M PED control input IRIS control input R BLK control input G BLK control input B BLK control input R GAIN control input G GAIN control input B GAIN control input Remote an...

Страница 23: ...utput Ground for tally signals OUT OUT OUT OUT GND This connector is used to output tally control signals BS side PRC05 RB5F1 Tajimi Cable side PRC05 P5M 5 pin male plug or equivalent COMMON TALLY OUT...

Страница 24: ...a waveform monitor BS side PRC03 21A10 7F Tajimi Cable side PRC03 12A10 7M10 5 7 pin male plug or equivalent External connection differs depending on the used waveform monitor Cable connection with e...

Страница 25: ...No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PRC03 12A10 7M10 5 1740 1741 1750 1751 GND CHROMA FILTER LOW PASS FILTER 2 LINE 2H V EXT BLANK WFM SEL REMOTE SYNC GND REMOTE SYNC ENABLE VECTOR SCH REMOTE ENABL...

Страница 26: ...IN Y AUDIO IN X AUDIO IN X AUDIO IN TIME CODE IN TIME CODE IN GND NC NC PRESET1 PRESET2 PRESET3 PRESET4 PRESET5 PRESET6 PRESET7 PRESET8 STORE DB 25P N DB C8 J10 B2 1 HOOD DB 25S WFM REMOTE FUNCTION N...

Страница 27: ...d for R and G TALLYs IN IN IN IN OUT GND This connector is used to input tally control signals BS side PRC03 21A10 7M Tajimi Cable side PRC03 12A10 7F10 5 7 pin female plug or equivalent For POWER the...

Страница 28: ...H PGM 1 line C PGM 1 line shield pins 13 and 14 PGM 2 line H PGM 2 line C PGM 2 line shield pins 16 and 17 REMOTE ISOLATE on off OFF OPEN ON GND HEAD INCOM MIC OFF Aspect ratio switching function ena...

Страница 29: ...the camera head to the control panel Digital data from the camera head to the control panel Digital data from the control panel to the camera head Digital data from the control panel to the camera he...

Страница 30: ...o the corresponding side of the rack mount adapter with two screws and a plate nut Connect both sides of the rack mount adapter to the corresponding lockings 19 inch rack 19 inch rack Locking Bar nut...

Страница 31: ...nt adapter with two screws BS 79 with an ADP plate Rack mount adapter dedicated to the BS 79 M3 6 6 To mount a RACK BLK secure the RACK BLK on an ADP plate with two screws 7 Secure the ADP plate on th...

Страница 32: ...s in the STATUS display mode a toolbar is displayed with a touch of the LCD touch sensor panel Only the functions the BS has are displayed If the toolbar display is left for about 5 seconds it automat...

Страница 33: ...aracters Sets the position where the BARS TITLE characters are displayed Sets the SDTV NTSC screen display mode Sets the V filter for the RET VIDEO up converter Sets the V filter for the SDTV output D...

Страница 34: ...ter vertical enhancer for the SDTV output You can select NARROW NORMAL WIDE or V WIDE The vertical resolution becomes higher in the following order NARROW NORMAL WIDE and V WIDE c INFORMATION INFORMAT...

Страница 35: ...ing a VTR Frame processing is performed so there are some afterimages STILL Suitable for shooting pictures and other still images OFF Suitable for shooting videos using a helicopter camera Field proce...

Страница 36: ...T knob on the RCP 50 to select a character to be displayed 4 Press the NEXT switch on the LCD touch sensor panel 5 Turn the CONTROL SELECT knob to select the column position of the character to be dis...

Страница 37: ...display position setting screen 2 Press the SEL switch on the LCD touchpanel 3 Turn the CONTROL SELECT knob on the RCP 50 to move the displayed characters right and left 4 Press the NEXT switch on th...

Страница 38: ...e inside the BS 79 2 MPU D A 2 MPU D A 1 U C D C 3 PULSE 4 AUDIO 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 C B A 9 8 7 6 5 4 3 210F E D C B A 9 8 7 6 5 4 3 210F E D MPU D A module S2 RCP ON OFF...

Страница 39: ...ed to control the camera head To grant the control right press the PANEL ENABLE switch on the target remote control panel Example 3 Parallel mode Blank panel RBK 79 OCP CCP MCP CCP OCP RCP 50 A dedica...

Страница 40: ...to S4 in the MON SD module For HDTV you can select the YPbPr or RGB signals using switches S2 to S4 in the MON HD module G S4 MON SD module Y R S2 Cr B S3 Cb G S4 MON HD module Y R S2 Pr B S3 Pb 4 4...

Страница 41: ...OFF position ON OFF S11 1 2 PULSE module Synchronization signal BBS Switch 2 The SDTV output and BBS are in phase The phase of the HDTV output leads the phase of the BBS by 90H The phase of the SDTV...

Страница 42: ...om lines of the external system 2LINE Two lines ENG cameraperson video engineer and PROD producer systems are available 1LINE The intercom from the PROD system is merged into the ENG system and one li...

Страница 43: ...S1 and S2 to the same position ENG ENG Normal position The ENG system is connected to the ENG system and the PROD system is connected to the PROD system ENG PROD For the system the ENG system is conne...

Страница 44: ...amera cable Action Check whether a cable is connected properly and check continuity of the cable to see whether there is an open If an open is found replace the cable with a new one SHORT Cause This i...

Страница 45: ...e cleaning method for male connectors slightly differs that for female connectors There is no difference between receptacles and plugs in the cleaning method Screw Hole only for male connectors Connec...

Страница 46: ...ove the swab back and forth when wiping the Ferrule Never move the swab round and round Swab Ferrule Good Ferrule Bad Magnified Ferrule section 3 Saturate a swab with alcohol and wipe the Ferrule with...

Страница 47: ...the end of the extractor that has an inner thread Extractor Section A Thread 1 Prepare a dedicated extractor and place the extractor in a position parallel to the connector 2 Remove the cap of sectio...

Страница 48: ...in a way in which the Ferrule is rubbed with foreign matters 6 After wiping the Ferrule with the swab saturated with alcohol wipe the Ferrule with a dry swab again 7 After cleaning the Ferrule check u...

Страница 49: ...lso displays self diagnostic information on the picture monitor for 20 seconds Self diagnostic information is not displayed on the VF Displaying the self diagnostic information screen Press the PM IND...

Страница 50: ...and SDI module temperatures are at least 85 C The REG and SDI module temperatures are at least 85 C The POWER REG and SDI module temperatures are at least 85 C or the RET HD temperature is at least 8...

Страница 51: ...Tsushinki Co Ltd Dec 2002 Ikegami Tsushinki Co Ltd All rights reserved Reproduction or duplication without permission of Ikegami Tsushinki Co Ltd of editorial or pictorial content in whole or in part...

Страница 52: ...2466738 IKETSU J Fax 03 5700 1160 Ikegami Electronics U S A Inc 37 Brook Avenue Maywood New Jersey 07607 U S A Phone 201 368 9171 Telex 219034 ITCNJ UR Fax 201 569 1626 Ikegami Electronics Europe GmbH...

Отзывы: