18
19
GB
Instruction Manual
Safety instructions
1. This anchor device, which complies with EN 795 (type B:2012, CEN/TS 16415:2013), has been tested and approved
for the provision of anti-fall protection for a maximum of 3 persons. In conjunction with the safety harnesses additionally
required complying with EN 361:2002, the IKAR HRA fall arresting devices complying with EN 360:2002 with rescue-
lifting equipment complying with EN 360:2002 / 1496:2007, it ensures the safety of persons when performing work
involving the risk of a fall. The anchor device and fall arresting devices shall only be used as intended.
Please note
: The IKAR fall arresting device (HRA) with rescue-lifting equipment is not included in the scope of delivery.
The enclosed instructions for the use and installation of this device shall be observed without fail.
2. Disregarding the instructions for use can risk causing death.
In event of a fall, it must be ensured that the person is not left hanging for more than 15 minutes (risk of suffering
shock).
3. A rescue plan that takes all potential emergencies in work-related scenarios into consideration must be in place.
4. The device must only be used by persons who have received the relevant training and who possess the appropriate
expertise. There shall be no factor present that might impair a person’s physical state. (e.g. alcohol, drugs, medication,
circulatory problems)
5. An optional IKAR fall arresting device (HRA) with rescue-lifting equipment can only be used to protect one person at a
time, but can be used by multiple persons one after another.
6. A suitable anchoring surface should be used for the assembly of IKAR sleeve. The cantilever arm is mounted by
inserting it into the IKAR sleeve.
7. Before each use, check to ensure the product label(s) are legible. A functional test should to be performed for the
optional IKAR fall arresting device (HRA), either by jerking the rope outward or applying a test weight of at least 15 kg.
The pawls must engage when this is done. Check to ensure that the snap hook is working properly.
8. The person performing work is secured once the cantilever arm has been correctly assembled, and the optional
IKAR fall arresting device (HRA) has been mounted in the mounting bracket on the cantilever arm and the end of the
extendible connector (snap hook) has been attached to a safety harness/lifebelt.
9. The device should be positioned as far as possible vertically above the head of the person who is to be protected in
order prevent pendulum movements in the event of a fall.
10. IKAR fall arresting devices for protecting persons must not be used on bulk materials or similar materials into which it is
possible to sink. It is crucial that work is protected in a way that minimizes the possibility of free fall. Prevent slack from
forming in the cable. There must be no possibility of impact with the ground or other obstacles in the event of a fall.
11. A system shall be taken out of use without delay if it has been damaged or strained by a fall, or if doubts exist
regarding the safe condition of the system. It may only be brought back into service after an expert has inspected it and
written approval has been obtained.
12. Depending on the degree of use, but at least once every 12 months, the anchor device shall be inspected by the
manufacturer or persons who have been trained and authorised by the manufacturer. This must be documented in the
enclosed test books. The effectiveness and durability of the anchor device depend on regular inspections.
13. If the cable breaks, kinks or frays, the optional IKAR fall arresting device shall be handed over to the repair workshop
for replacement of the cable.
14. DGUV R 112-198 and DGUV R 112-199 shall be observed.
15. According to EN 360:2002 the optional IKAR fall arresting device can be used in a temperature range of -40 to +50 °C.
16. The permissible load on the anchor device complies with EN 795 Type B:2012, CEN/TS 16415:2013 for the protection
of 3 persons.
17. The cantilever arm and the optional IKAR fall arresting device should be protected from the effects of welding torches
and sparks, fire, acids, alkalis as well as extreme temperatures and other similar environmental influences. The anchor
device and any optional equipment should be stored in a clean, dry and well-ventilated place after use until they are
required again. The equipment shall be protected against impact during transport.
18. No modifications or additions may be made to the overall system.
Содержание ASS-3
Страница 4: ...4...
Страница 12: ...12...
Страница 89: ...89 IKAR IKAR A B C ASS 3 A B C GR...
Страница 90: ...90 1 2 3 4 5 HRA HRA IKAR PLW IKAR 2 IKAR HRA 2 2 HRA 1 3 4 IKAR 5 3 4 GR...
Страница 91: ...91 1 2 3 4 5 RL 2006 42 IKAR PLW IKAR PLW IKAR IKAR 41 54 AWS M10x16 PLW IKAR IKAR IKAR IKAR 1 2 IKAR GR...
Страница 92: ...92 2 3 2 1 2 1 2 HRA...
Страница 93: ...93...
Страница 94: ...94...
Страница 95: ...95...