background image

www.ikancorp.com | 1.713.272.8822 | [email protected] 

because we’re 

filmmakers

 too

Periodic Fixture Inspection

1.  The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 hours or at least once a year. This frequency 

may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar spare parts.

2.  The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise explosion 

might occur. Defer to instructions provided by the lamp manufacturer.

3.  Always check the safety shield before every use.
4.  All high-voltage components (ex:voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a 

year).

5.  Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow 

inspections of accessories and the holding clamps.

6.  The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or broken. 

It is essential for the performance of the fixture.

Specifications

Optional Accessories

Some other products that work well with the LSP-001 available from Ikan include:

LEB-003A
KCP-703

575/1200 Watt Electronic Ballast (Lightstar)
Stage Clamp with 16mm Stud

Fixture Specifications

Beam Angle

6-42°

Build Material

Aluminum

Color Temperature

5600K

Control

Focus Knob

Fixture Size

27.2 x 16.5 x 18.2 in.

Fixture Weight

35 lbs

IP Class

IP23

Lamp Base

1200W / 100V / G38

Lens

10

"

LUX: (Flood)

3m: 22000 lux

5m: 7900 lux

10m: 1980 lux

LUX: (Spot)

3m: 183000 lux

5m: 66000 lux

10m: 16500 lux

Отзывы: