background image

IKA-Werke GmbH & Co.KG

Janke & Kunkel-Str. 10
D-79219 Staufen
Tel. +49 7633 831-0
Fax +49 7633 831-98
[email protected]

www.ika.com

Содержание T25 easy clean digital

Страница 1: ...Operating instructions EN 20000017329a T25 easy clean digital control_072018 IKA T25 easy clean digital IKA T25 easy clean control ...

Страница 2: ...arts Dangerous parts Device setup Item Designation 1 Operator panel and display 2 Turning knob 3 Dispersion tool 4 USB port 5 Stand 6 Extension arm 7 Cross sleeve 8 Power switch 9 Strap clamp Fig 1 4 5 6 7 8 9 On Off 3 2 1 Fig 2 ...

Страница 3: ...n of conformity 3 Explication of warning symbols 3 Safety instructions 4 Intended use 5 Unpacking 6 Useful information 6 Drive 6 Securing 7 Operator panel and display 8 Commissioning and operating 10 Interfaces and outputs 12 Accessories 13 Permitted dispersion tools 13 Warning message 14 Error codes 14 Maintenance and cleaning 15 Technical data 16 Warranty 16 WARNING We declare under our sole res...

Страница 4: ...ions guidelines occupational health and safety and accident prevention regulations Please pay attention to the danger ous parts of the equipment in Fig 2 Beware of the risk of flammable materials glass breakage sharp edges on the dispersing tool Wear your personal protective equipment in accordance with the hazard category of the media to be processed There is a risk from splashing and evaporation...

Страница 5: ...e device without tools must later be refitted to ensure safe op eration This will prevent the infiltration of foreign objects liquids and other contaminants Never run dispersion tools dry as the gasket and bear ings will be destroyed if the tools are not cooled by the medium In the event of unbalance or unusual noises switch off the device immediately Replace the dispersion tool If there is no dif...

Страница 6: ... and thrust forces In addition high turbulence occurs in the shear gap between rotor and stator which provides optimum mixing of the suspension The dispersion effectiveness is heavily dependent on the product of the shear gradient and the time the particles spend in the shear zone The optimum range for the cir cumferential velocity of the rotor stator arrangement is 6 24 m s A processing time of a...

Страница 7: ...tion may cause the screw to become loose It is there fore necessary for safe use to regularly check that the exten sion arm is attached securely Tighten the hexangular bolt as required Securing the disperser to the stand Check that the disperser is held in position firmly prior to each use and also at regular intervals The position of the disperser must only be adjusted when the equipment is sta t...

Страница 8: ...Stop knob Set the speed Set the timer when Timer setting is activated Start stop dispersing function L On off button Switch on off the device M Timer button Switch between the setting of speed and timer N min sec indicator Indicate the Timer or Counter is in minute second min sec mode O Timer setting indicator Indicate the Timer can be set P Speed setting indicator Indicate the speed can be set Wh...

Страница 9: ...spersion tool indicator Indicate the S 25 EC T dispersion tool is in serted J S 25 EC T dispersion tool button Display the remaining time to maintenance of S 25 EC T tool Activate the reset of the maintenance time K Start Stop knob Set the speed value by rotating the knob Set the timer value by rotating the knob when Timer setting is activated Start stop the running of the device by press ing the ...

Страница 10: ...the device by pressing on off button L After a beep the Speed setting indicator P lights up Change the speed setting by rotating the Start Stop knob K The speed value shows on the display A e g means the speed is 3200 3 2 x 1000 rpm Start the device by pressing the Start Stop knob K Note After starting actual speed value flashes until reach the set value Setting speed Switching on After switching ...

Страница 11: ...0 the device will not stop but we recommend a maintenance of the tool as soon as possible After the maintenance in a IKA service workshop the maintenance time will be reset from the service team In all other cases it is possible to reset the maintenance time with the device Description see below To check the tool maintenance time of S 25 EC T by pressing S 25 EC T dispersion tool button J Display ...

Страница 12: ...et Commands are generally sent from the computer Master to the device Slave The device sends only at the computer s request Even fault indications cannot be sent spontaneously from the device to the computer automation system Commands are transmitted in capital letters Commands and parameters including successive parame ters are separated by at least one space Code hex 0x20 Each individual command...

Страница 13: ... Stainless steel S 25 D 10 G KS Synthetic material S 25 D 14 G KS Synthetic material S25 KD 18 G Stainless steel S25 KD 25 G Stainless steel S25 KD 25 F Stainless steel S25 KD 18 G ST Stainless steel S25 KD 25 G ST Stainless steel S 25 EC C 18G ST Stainless steel S 25 EC T C 18G ST Stainless steel S 25 EC only suitable for T25 easy clean digital or T25 easy clean control Full functionality of the ...

Страница 14: ...function during operation may be identified by an error message on the display Proceed as follows in such cases Switch off device using the power switch Carry out corrective measures Restart the device Error code Cause Effect Solution E 3 Inside temperature is too high motor off Switch off the device and let it cool down Restart the device E 4 Motor can t run normal can t start or not reach the ta...

Страница 15: ...be placed in the cleansing agent for the purpose of cleaning Do not allow moisture to get into the device when cleaning Before using another than the recommended method for cleaning or decontamination the user must ascertain with IKA that this method does not destroy the device Spare parts order When ordering spare parts please give machine type manufacturing number see type plate item and designa...

Страница 16: ...25 easy clean control Operating voltage VAC 220 240 10 100 120 10 Frequence Hz 50 60 Motor rating input W 500 Motor rating output W 400 Volume range H2O l 0 001 2 Maximum viscosity mPa s 5000 Speed range rpm 3000 25000 Speed deviation 2 of current speed Speed display LED Speed adjustment stepless Noise without dispersion tool dB A 70 Extension arm Ø x L mm 13 x 160 Temperature display no LED Tempe...

Страница 17: ...IKA Werke GmbH Co KG Janke Kunkel Str 10 D 79219 Staufen Tel 49 7633 831 0 Fax 49 7633 831 98 sales ika de www ika com ...

Отзывы: