background image

32

   ›  The device is maintenance-free� It is only subject to the natural wear and tear of components 

and their statistical failure rate�

/// Cleaning:

   › For cleaning disconnect the mains plug!
  › Use only cleaning agents which have been approved by IKA to clean IKA devices�

These are water (with tenside) and isopropanol�

   › Wear protective gloves during cleaning the devices�
   › Electrical devices may not be placed in the cleansing agent for the purpose of cleaning�
   › Do not allow moisture to get into the device when cleaning�
   › Before using another than the recommended method for cleaning or decontamination, the

user must ascertain with IKA that this method does not destroy the device�

/// Spare parts order:

› When ordering spare parts, please give:

- device type�
- serial number, see type plate�
- software version (upon device starting up)�

/// Repair:

  Please only send devices in for repair that have been cleaned and are free of materials which

 

might present health hazards�
If your appliance requires repair, return it in its original packaging� Storage packaging is not

 

sufficient when sending the device - also use appropriate transport packaging�

Maintenance and cleaning

Содержание Plate RCT digital

Страница 1: ...IKA Plate RCT digital RCT 5 digital...

Страница 2: ...Fig 1...

Страница 3: ...l Data 36 EU Declaration of conformity 6 Explication of warning symbols 6 Interfaces and outputs 29 Operator panel and display 15 Warranty 38 Maintenance and cleaning 32 Accessories 32 Intended use 10...

Страница 4: ...nor mative documents EN 61010 1 EN 61010 2 010 EN 61010 2 051 EN 61326 1 EN 60529 and EN ISO 12100 A copy of the complete EU Declaration of Conformity can be requested at sales ika com Source language...

Страница 5: ...heating plate can reach dangerous temperatures Pay attention to the residual heat on the heating plate after switching off the stirrer The device may only be transported when the heating plate has co...

Страница 6: ...s well as with fine powders of metals in groups 2 and 3 of the periodic system at temperatures above 300 C 400 C Only elementary fluorine chlorotrifluoride and alkali metals attack it halogenated hydr...

Страница 7: ...d from the mains outlet by pulling out the power cord set or the connector plug For protection of the equipment The device may only be opened by qualified and IKA approved experts Do not cover the dev...

Страница 8: ...h teaching trade or industry area The safety of the user cannot be guaranteed if the device is operated with accessories that are not supplied or recommended by the manufacturer if the device is opera...

Страница 9: ...rail or freight forwarding company Scope of delivery 1 IKA Plate RCT digital RCT 5 digital 2 Power cord 3 USB cord 4 Temperature sensor PT 1000 60 5 Screwdriver safety circuit 6 Magnetic stir bar IKA...

Страница 10: ...device must not be suspended from the support rod Risk of tipping Make sure that the center of mass of the attached device does not protrude over the safe area indicated below with a dotted rectangle...

Страница 11: ...n M 3 Switch on the device via the main switch A Temperature sensor PT 1000 The actual temperature value shown on the display corresponds to the temperature of the medium The symbol shows on the displ...

Страница 12: ...14 1 2 1 2 3 OFF 20 mm...

Страница 13: ...ng D Rotating pressing knob Speed setting E Menu button F Timer button G Lock button H Display Operator panel I Standby LED J Power socket K USB Interface L RS 232 Interface M Connection for PT 1000 t...

Страница 14: ...lue 08 Actual speed value 09 Temperature control mode 10 Operating mode 11 Safety circuit temperature 12 Viscosity trend value 13 14 PT 1000 temperature sensor connected ETS D5 ETS D6 connected 15 All...

Страница 15: ...17 Operation Start up 1 2 OFF C F rpm 3 4 Temp 0 310 C Speed 0 1500 rpm SET SET SAFE 5 ON...

Страница 16: ...on the right of the display Press the rotating pressing knob D to start the stirring function Temp 0 310 C Speed 0 1500 rpm SET SET SAFE Temp 0 310 C Speed 0 1500 rpm SET SET SAFE Temp 0 310 C Speed...

Страница 17: ...rature limit can be adjusted using a screwdriver Do not turn the setting screw beyond the clockwise or anticlockwise stop This will cause irrep arable damage to the potentiometer Functional test safet...

Страница 18: ...SET SAFE Temp 0 310 C Speed 0 1500 rpm SET SET SAFE Temp 0 310 C Speed 0 1500 rpm SET SET SAFE Temp 0 310 C Speed 0 1500 rpm SET SET SAFE Temp 0 310 C Speed 0 1500 rpm SET SET SAFE 0 310 C Safe temp...

Страница 19: ...alues please refer to the operating manual of the device you are connecting The desired average temperature can be adjusted on the contact thermometer The required surface temperature of the heating p...

Страница 20: ...00 03 mm ss Clockwise continuous ON OFF Beep ON OFF Temperature unit C F Timer expired yes no yes no Stop heating Stop stirring Safe Visc Safe Visc SAFE Factory reset yes no Probe calibration not def...

Страница 21: ...s to be confirmed by pushing one of the rotating pressing knobs During operation in mode D the device behaves the same as in Mode A with the exception that The temperature speed setting must be confir...

Страница 22: ...ion Error 5 is taken to recognize that the sensor has not been placed in the medium when the heating is switched on Notice You can set a value from 0 5 to 30 min for this time limit depending on the a...

Страница 23: ...cannot be used in conjunction with torque trend meas urement The current control variable is saved as the reference 100 P and shown on the digital dis play The change in the viscosity is then shown i...

Страница 24: ...item to Software version Press the Timer button for 2 seconds to activate the timer counter function Timer Counter SET SET SET 2nd temp EXT temp SET SET SAFE SET SET SAFE SET SET SAFE SET 1st temp 1s...

Страница 25: ...27 1 2...

Страница 26: ...on the menu setting Counter mode count up To select the counter mode you must set all the values to 00 00 00 The value is confirmed by pressing the rotating pressing knob D Pressing the button F to st...

Страница 27: ...1 For the electrical characteristics of the interface and the allocation of signal status standard RS 232 applies in accordance with DIN 66 259 Part 1 Transmission procedure asynchronous character tra...

Страница 28: ...temperature value IN_SP_4 Read rate speed value OUT_SP_1_x x 0 310 Adjust the set temperature value OUT_SP_4_x x 0 1500 Adjust the set speed value START_1 Start the heater STOP_1 Stop the heater STAR...

Страница 29: ...the computer and the device Watchdog mode 1 If there is an interruption in data communications longer than the set watchdog time the heating and stirring functions are switched off and Er02 is displa...

Страница 30: ...es These are water with tenside and isopropanol Wear protective gloves during cleaning the devices Electrical devices may not be placed in the cleansing agent for the purpose of cleaning Do not allow...

Страница 31: ...off motor switched off Solutions reduce load torque or use smaller magnetic rods reduce target speed Er05 No temperature increase measured by temperature sensor selected time in menu Causes sensor no...

Страница 32: ...uring heating plate safety test Causes S_CHECK cannot generate H_S_TEMP Effect heating switched off Solutions switch device off leave to cool and switch on again Er24 Heating plate temperature is high...

Страница 33: ...y temperature sensor Effect heating switched off Solutions switch device off leave to cool and switch on again ensure regular heat dissipation when using metal blocks etc on the flat surface of the he...

Страница 34: ...class according to DIN EN 60529 IP 42 Protection class I Contamination level 2 Overvoltage category II Plate material Aluminium alloy Aluminium with ceramic coating Plate dimensions 135 mm 137 x 137...

Страница 35: ...H 1500 6 5 K min 7 5 K min Temperature control accuracy of heating plate at 100 C 5 K Adjustable safety circuit 50 C 370 C External temperature sensor thermometer Connection for external temperature s...

Страница 36: ...ay also send the device direct to our factory enclosing the delivery invoice and giving reasons for the claim You will be liable for freight costs The warranty does not cover worn out parts nor does i...

Отзывы: