Safety instructions

/// General information

› 

Read the operating instructions completely before starting up and follow the safety 

instructions.

›  Keep the operating instructions in a place where it can be accessed by everyone�
›  Ensure that only trained staff work with the device�
›  Follow the safety instructions, guidelines, occupational health and safety and accident 

prevention regulations�

›  The vessel must only be used in a technically perfect condition�
›  Refer to the operating instructions for the drive unit�

  Danger!  

›  Please observe the relevant safety instructions and guidelines regarding dust explosions�

 Caution!   

›  Wear your personal protective equipment in accordance with the hazard category of the 

medium to be processed, there is a risk of:
- body parts, hair, clothing and jewellery getting caught
- sharp blade edges�

!

 Notice!

›  Pay attention to the marked sites in Fig� 1� 
›  Protect the vessel from bumping and impacting�
›  Do not use any damaged vessel e�g� with hairline cracks or splits�
›  Check the vessel beforehand for damage each time when you use them� Do not use dam-

aged components�

/// Device setup

!

 Notice!

›  Ensure that the vessel and the cover is firmly attached to the drive unit prior to operating the 

device�

›  The drive unit cannot be operated without a closed vessel� 

Source language: German

Explication of warning symbols

/// Warning symbols

Indicates an (extremely) hazardous situation, which, if not avoided, will 
result in death, serious injury�

Danger!

Indicates a hazardous situation, which, if not avoided, can result in 
death, serious injury�

Warning!

Indicates a potentially hazardous situation, which, if not avoided, can 
result in injury�

Caution!

!

Indicates practices which, if not avoided, can result in equipment damage�

Notice!

/// General Symbols

Position number

A–––

Correct / Result
Shows the correct execution or the result of an action step�

Wrong
Shows the incorrect execution of an action step� 

Note
Displays action steps that require particular attention to detail� 

/// Working with the vessel

  Danger!  

›  With substances capable of forming an explosive mixture, appropriate safety measures must 

be applied, e�g� working under a fume hood�

›  To avoid body injury and property damage, observe the relevant safety and accident preven-

tion measures when processing hazardous materials�

 

Warning!    

›  Only process samples that will not react dangerously to the extra energy produced through 

processing� This also applies to any extra energy produced in other ways, e�g� through light 
irradiation�

!

Содержание MultiDrive MI 250

Страница 1: ...IKA MultiDrive MI 250 IKA MultiDrive MI 400 IKA MultiDrive MI 250 T IKA MultiDrive MI 400 T...

Страница 2: ...3 ENGLISH...

Страница 3: ...4 5 Installation 12 Explication of warning symbols 6 Safety instructions 7 Unpacking 8 Technical Data 25 Warranty 24 Maintenance and cleaning 18 Accessories 24 Useful information 9 Fig 1...

Страница 4: ...e cover is firmly attached to the drive unit prior to operating the device The drive unit cannot be operated without a closed vessel Source language German Explication of warning symbols Warning symbo...

Страница 5: ...for cooling liquid up to max 1 bar When using dry ice note the freezing point of the coolant in the cooling circuit and the increase in pressure in closed vessels The processing time is limited depend...

Страница 6: ...250 1 MI 400 1 can grind soft medium hard and brittle materials with a Mohs scale of hardness of up to 5 For harder material the wear and tear on the grinding tool is high and grinding therefore beco...

Страница 7: ...tion to the maximum filling level 2 Click Click 1 4 3 1 2 green Note After the cap has been securely closed the color of the LED signal lamp changes from red to green The unit is only ready for operat...

Страница 8: ...When cooling the vessel with tap water proceed as following Note during the filling process turn the vessel upside down After water comes out of the outlet hose the system is filled Then turn back and...

Страница 9: ...spray into the venting slot of the drive unit Empty the cooling circuit Notice Empty the cooling liquid completely if you use the vessel without cooling Otherwise the temperature will increase and the...

Страница 10: ...tion the user must ascertain with that this method does not destroy the device Wear protective gloves during cleaning the vessel Notice Don t damage the sealing on the vessel cap when cleaning Sealing...

Страница 11: ...se observe the safety instructions To loosen the retaining nut of the grinding tool turn the socket wrench in clockwise direction left hand thread 1 2 3 3 4 1 2 3 5 For thoroughly cleaning the bearing...

Страница 12: ...aging is not sufficient Please also use suitable transport packaging Ordering spare parts When ordering spare parts please indicate Vessel type Item and designation of the spare part see www ika com s...

Страница 13: ...250 400 250 400 Grinding tools material Stainless steel Grinding chamber material Stainless steel Standard milling tool diameter mm 71 81 71 81 Max circumferential speed m s 75 85 75 85 Allowed speed...

Страница 14: ...162 eMail sales england ika com MALAYSIA IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ika cn POLAND IKA Poland Sp z o o...

Отзывы: