13.5 Menu structure:
13.5.1 Main menu
Stirrer
Temperature
Limits
Minimum.………………………………… 10 °C
Maximum.……………………………….... 60 °C
Calibration Sensor...............................................………………………... -
Reset Calibration...................................................................................... -
Timer
Time……………………………………………………………………….. 00:00:00:00 [dd:hh:mm:ss]
Actions after expiry
Mixing Speed.…………………………...... 0 rpm
Temperature.……………………………… 10 °C
Light Intensity............................................ 10 %
Gas 1......................................................... closed
Gas 2......................................................... closed
Pump 1...................................................... 0 ml/min
Pump 2...................................................... 0 ml/min
Stop all functions...................................... deactivated
Beep.......................................................... deactivated
Activate................................................................................................... deactivated
Start........................................................................................................ -
Factory settings
File
manager
pH Sensor
File List
Files……..................................................... -
Sampling Rate............................…………………………………………. 01:00 [mm:ss]
Start Recording...........................…………………………………………. deactivated
Values that can be stored
Set Speed……….........................………... activated
Actual Speed……..............……………..... activated
Actual direction of rotation (stirrer)............. activated
Actual light intensity................................... activated
Set Temperature......................................... activated
Actual thermostat temperature.................. activated
Actual temperature sensor.......................... activated
Actual liquid level (thermostat).................... activated
Actual pH value.......................................... activated
Actual pump 1 flow................................... activated
Actual pump 2 flow................................... activated
Actual gas 1 status..................................... activated
Actual gas 2 status..................................... activated
Separator
“,” and “;”.................................................. “,”
Sensor Connected.....................................................………………….... deactivated
Calibration Sensor...............................................………………………... -
Reset Calibration...................................................................................... -
Limits
Minimum…………………………….......... 5 rpm
Maximum.……………………………........ 100 rpm
Pumps
Limits
Calibrate Pumps
Pump 1.………………………………….... -
Pump 2.…………………………………… -
Reset Calibration.....................................................................................
-
Pump 1
Minimum.………...…. 60 ml/min
Maximum.…………... 450 ml/min
Pump 2
Minimum.………........ 60 ml/min
Maximum.…………… 450 ml/min