VENTING INSTALLATION
Continued
FIRESTOP SPACERS (FS-10)
Figure 11 - Typical Offset Terminations
Return
Elbow
Offset
Elbow
Return
Elbow
Offset
Elbow
6' Max.
6' Max.
6' Max.
6' Max.
6' Max.
6' Max.
Return
Elbow
Offset
Elbow
Offset
Elbow
Return
Elbow
A
B
C
Offset
Elbow
Ceiling
Support Pipe
12S-12DM
Return
Elbow
Figure 12 - Firestop Spacer with Living Space Above Ceiling
Figure 13 - Firestop Spacer with Attic Space Above Ceiling
Existing
Ceiling
Frame
Firestop
Spacer
Screws or
Staples
(Min. of 8)
Firestop
Spacer
Screws or Staples
(Min. of 8)
Existing
Ceiling
Frame
Firestop spacers are required at each point where the chimney
penetrates a floor space. Their purpose is to establish and maintain
the required clearance between the chimney and the combustible
materials. When the pipe passes through a framed opening into a
living space above, the firestop must be placed onto the ceiling from
below as shown in Figure 12.
They also provide complete separation from one floor space to
another or attic space as required by most codes. When the double
wall pipe passes through a framed opening into an attic space, the
firestop must be placed into an attic floor as shown in Figure 13.
Firestop Thimble FST10
Figure 13a - Firestop Thimble
IMPORTANT NOTICE
When penetrating a ceiling into an attic, a firestop
thimble (FST10) is required to avoid intrusion by in-
sulation and recommended to negotiate a joist.