NOTE: It is important to ensure proper log and or media placement
per the manual when installing these units. Verify pilot flame is not ob-
structed.
Reference manual to test fire unit and verify proper operation.
If all other steps of Baffle replacement and door brackets
have been completed, field service for rear venting unit
is complete with the installation of the Block-Off Plate.
4a. Remove pilot head by pulling up firmly, discard it and
verify proper pilot gas setting. For Natural gas units the
orifice should be turned counter-clockwise. For Propane
(LP) gas units the orifice should turned clockwise. Some
pilot orifices require a small flat standard screwdriver and
some require a 4mm allen type wrench to rotate the orifice
in the pilot cavity. See Figure 13a and 13b.
4b. Install new pilot head provided in this kit by pressing down
firmly until a click is heard. Verify that the pilot head is
properly installed by lightly pulling up and verifying the
spring is still installed. See Figure 13a.
4c. After Pilot hood replacement, Discard the old pilot hood,
light the pilot and verify the ignition is correct per the
installation instructions.
Figure 13
Pilot Hood
Pilot Hood
Cavity
A
B
Figure 14 - Pilot Hood
Pilot Hood
Pilot Hood Removed