901176-00 NC
10
ihp.us.com
BOX INSTALLATION
1� The EIS box comes with a 120" pilot assembly lead� Therefore, the
box must be mounted within 9' of the fireplace�
2� Attach the metal enclosure to the studs using standard building
materials� The metal enclosure must be mounted in a location
that can be accessed in the future for additional connections and
future servicing�
GAS LINE INSTALLATION
• Installation and sevicing of gas appliances and ignition systems
must only be performed by
qualified personnel
�
• Turn off gas and electricity before starting installation or service�
• Make sure gas piping is pressure tested before control is con-
nected� High pressure can damage the control casuing a hazard-
ous condition�
• Make sure piping is clean and free from burrs� Apply a small
amount of good quality pipe thread compound or plumbers'
tape suitable for the gas being used� Thread compound should
be used sparingly on male threads only, leaving the first two
threads clean�
• It is recommended that a safety shut off valve is installed on either
the gas in or gas out side of the valve�
• It is recommended to hard pipe in the connections with unions
installed inside the box�
Gas In
Gas Out
PILOT INSTALLATION
• Un-coil the pilot tubing and the spark ignitor using proper alumi-
num tubing bending techniques�
• Insert the pilot hood w/assembly into the fireplace being careful
not to clog the head of the pilot assembly or damage the spark
ignitor�
• Securely screw the pilot assembly to the pilot mounting bracket
on the back or side of the burner� Screwing the pilot to the burner
completes the electrical circuit�
• With the opposite end of the pilot assembly, plug the orange spark
ignitor into the module according to the wiring diagram(s) found
on
Page 17
and insert the pilot tubing into the right side of the
valve where the compression nut is located� Once the pilot tubing
is inserted into the compression nut, using a wrench, tighten the
nut so that the pilot tubing cannot be pulled out�
EIS BOX INSTALLATION
BOTH CONTROL BOX AND BURNER ARE REQUIRED TO
COMPLETE THIS SYSTEM IN ORDER TO SATISFY THE
Z.21.60 STANDARD.
FOR USE WITH NATURAL GAS ONLY!
INSTALLATION
Continued
9'
For remote and wall switch wiring, refer to
Page 12
�