background image

 

_________________________________________________________________________________________________________________________ 

REV. 7-29-15    Page 3 of 4 

Model: 4001 & RCKIT4001 

 

       WIRING INSTRUCTIONS 

 

A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote 
should install the remote control system.  Incorrect wiring connections 

WILL

 cause damage to the gas valve or electronic module 

operating the gas appliance and may also damage the remote receiver.   
 

 
WIRING MILLIVOLT VALVES 

The remote receiver is connected to the millivolt valve using the TH (thermostat) terminals on the terminal block on the millivolt gas 
valve.  Connect 18 gauge solid or stranded wires from the remote receiver to the gas valve. 
 
 

 

Operation of the remote receiver is similar to that of a thermostat in that both turn the gas 

valve  

on and off based on input signals.  A thermostat’s input signals are different temperatures.  

The  

remote receiver’s input signals come from the transmitter. 

 

 

Connect one of the two wires leading from the receiver to the TH terminal and the other to 

the  

TH/TP terminal on the millivolt gas valve it does not matter which wires go to which 

 

terminal.   

 
 
 
 
 

WIRING ELECTRONIC SPARK IGNITIONS 

 
 
 
 

 

The remote control receiver can be connected, in series between a 24VAC transformer  
and the TR terminal on the ELECTRONIC MODULE.  Connect the hot wire from the 
24VAC transformer to either of the wires on the remote receiver.  Connect the other wire 
on the receiver (wires included) terminal and the TH (thermostat) terminal on the 
ELECTRONIC MODULE. 

 

 

 
 
SYSTEM CHECK 

 

MILLIVOLT VALVES AND ELECTRONIC SPARK IGNITION SYSTEMS 

 
Light your gas appliance following the lighting instructions that came with the appliance.  Confirm that the pilot flame is on; it must be in 
operation for the main gas valve to operate.   
 

 

Slide the 3-position button on the remote receiver to the ON position. On millivolt systems the main gas flame (i.e., the fire) 
should ignite. On Electronic ignition systems the spark electrode should begin sparking to ignite the pilot (the pilot may ignite 
after only one spark). After the pilot flame is lit, the main gas valve should open and the main gas flame should ignite. 

 

Slide the button to OFF.  On millivolt systems the flame should extinguish (the pilot flame will remain on). On electronic ignition 
systems the main gas flame and pilot flame should BOTH extinguish. 

 

Slide the button to REMOTE (the center position), and then press the ON button on the transmitter to change the system to 
ON.  The main gas flame should ignite. On Electronic ignition systems the spark electrode should begin sparking to ignite the 
pilot (the pilot may ignite after only one spark).  After the pilot flame is lit, the main gas valve should open and the main gas 
flame should ignite. 

 
 
 
 
 

 

TERMINAL BLOCK

ON MILLIVOLT

GAS VALVES

TH

TP

TP

TH

THERMOPILE/

PILOT LIGHT

REMOTE

RECEIVER

 

ELECTRONIC MODULE

TR

TH

REMOTE

RECEIVER

neutral wire

24VAC

hot wire

120VAC

110/24VAC

Transformer

 

Содержание 4001

Страница 1: ...plus side up Note the drawing at the left It is recommended that a CR2032 lithium battery always be used for longer battery life and maximum operational performance REMOTE RECEIVER The remote receiver operates on 4 AA size 1 5V batteries It is recommended that ALKALINE batteries be used for longer battery life and maximum microprocessor performance IMPORTANT New or fully charged batteries are esse...

Страница 2: ...ALL MOUNTING Install 4 AA size 1 5 ALKALINE batteries in the remote receiver For best performance remote receiver batteries should be factory fresh when installed Very little battery power is required to operate the remote receiver but the electronics are tuned to operate best when battery output is greater than 5 3 volts Four new AA batteries should provide an output voltage of 6 0 to 6 2 volts B...

Страница 3: ...wire from the 24VAC transformer to either of the wires on the remote receiver Connect the other wire on the receiver wires included terminal and the TH thermostat terminal on the ELECTRONIC MODULE SYSTEM CHECK MILLIVOLT VALVES AND ELECTRONIC SPARK IGNITION SYSTEMS Light your gas appliance following the lighting instructions that came with the appliance Confirm that the pilot flame is on it must be...

Страница 4: ...r than 20 feet The transmitter should operate with as little as 2 5 volts battery power TROUBLE SHOOTING If you encounter problems with your fireplace system the problem may be with the fireplace itself or it could be with the remote Review the fireplace manufacturer s operation manual to make sure all connections are properly made Then check the operation of the remote in the following manner Mak...

Отзывы: