- 8 -
10.2013
Layout & configuration
robolink
®
Igus Motion Editor
igus GmbH
Spicher Strasse 1a, 51147 Cologne, Germany
Tel: +49-(0)2203 / 9649-7331
eMail: [email protected]
3.
Prepare terminating resistors: 120Ω resistor between pin 2+7 and 4+9
Use D-Sub connector with solder cup (Conrad 742066-05).
4.
Interface cable Crumb2560 (igus CF130.03.05.UL)
Use D-Sub plug with solder cup (Conrad 742082-05).
Pin D-Sub
Pin Crumb2560
2
3
4
3
7
2
8
1
9
2