background image

 

REFRIGERATION LTD 

 

www.igloorefrigeration.com

 | 

Pastry Cases

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1 – Stainless steel upper shelf 
2 – Evaporator coil 
3 – Rail (condensate outflow after defrosting the 

evaporator) 

4 – Sliding door 
5 – Inner frame 
6 – Compressor 
7 – LED lamp  
8 – Cured front glass 
9 – Base of the unit (DO NOT BLOCK air louver!!!) 
10 – ABS sides  
11 – Control panel 
12 – Condenser cover (DO NOT BLOCK air louver!!!) 
13 – Leveling legs  
14 – Serial plate 
15 – Straight front glass 

 

2.3. Technical data  

Table 1 Technical data  

Model 

Voltage 
[V/Hz/Ph] 

Rated Current 
[A] 

Max shelf load 
[lbs/kg] 

Weight   
[lbs/kg] 

JSCRP4/J2SCRP4 

115/60/1 

8 (max.fuse:15) 

66/30 

337/153 

JSCRP6/J2SCRP6 

115/60/1 

8 (max.fuse:15) 

66/30 

529/240 

JSCRP8//J2SCRP8 

115/60/1 

15 (max.fuse:20) 

66/30 

661/300 

Figure 1  JSCRP and J2SCRP

 

J2SCRP 

(Straight glass) 

 

JSCRP 

(Cured glass) 

 

Содержание JSCRP

Страница 1: ...Pastry Display Cases Models JSCRP and J2SCRP JSCRP J2SCRP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Страница 2: ...Temperature regulation 8 5 MAINTENANCE 9 5 1 Cleaning and maintenance 12 6 SERVICE 13 6 1 Faults identification and repair 13 6 2 Service 14 List of Figures Figure 1 JSCRP and J2SCRP 4 Figure 2 Level...

Страница 3: ...n the environment and the location of the unit 2 2 Description of the unit JSCRP and J2SCRP display cases have static cooling The display case is equipped with automatic condensate evaporation and aut...

Страница 4: ...louver 10 ABS sides 11 Control panel 12 Condenser cover DO NOT BLOCK air louver 13 Leveling legs 14 Serial plate 15 Straight front glass 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph...

Страница 5: ...y be turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil In...

Страница 6: ...disassembled If the user received the unit partially disassembled perform the following operations 1 Place the Fixed shelf grip in perforated frame strip Figure 3 5 2 Mount cross bars Figure3 3 and Fi...

Страница 7: ...d aggregate operating cycle may fluctuate This depends on numerous factors such as amount and temperature of products placed in the device and the temperature of the surroundings The equipment should...

Страница 8: ...ranty Do not use electric devices inside the product storing chamber Avoid unnecessary opening of doors and leaving them open for a longer period of time 4 1 Temperature regulation The thermostat is t...

Страница 9: ...1 sec displays sets the set point more than 3 sec accesses the parameter setting menu enter password 22 mutes the audible alarm buzzer Start Up hold the set mute button for 1 sec RESET current EY set...

Страница 10: ...e category of parameters will be on Press SET to display the value associated with the parameter Increase or decrease the value using the UP or DOWN button respectively Press SET to temporarily save t...

Страница 11: ...absolute relative temperature for low temperature alarm 0 0 C 50 99 AH absolute relative temperature for high temperature alarm 0 0 C 50 99 Ad temperature alarm delay 0 min 0 199 A4 3rd input configur...

Страница 12: ...attention not to damage the temperature sensor It is recommended to make a break in the operation once a month in order to clean the interior naturally defrost the evaporator and clean the condenser I...

Страница 13: ...equipment is not working Make sure that The equipment is connected to the power supply The Voltage and frequency in the network are compliant with those recommended by the manufacturer 115V 60Hz The m...

Страница 14: ...Each compressor makes certain noises when operating These sounds are made by the aggregate engine and by cooling agent flowing through the circuit This phenomenon constitutes a technical feature of co...

Отзывы: